Lancaster - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Lancaster

Lancashire · BBC Radio Lancashire (FM) · 104.5 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 1.05 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 2 dB attenuation; relative ERP 63.1% of peak 10°: 2 dB attenuation; relative ERP 63.1% of peak 20°: 3 dB attenuation; relative ERP 50.1% of peak 30°: 3 dB attenuation; relative ERP 50.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 3 dB attenuation; relative ERP 50.1% of peak 60°: 2 dB attenuation; relative ERP 63.1% of peak 70°: 2 dB attenuation; relative ERP 63.1% of peak 80°: 2 dB attenuation; relative ERP 63.1% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 3 dB attenuation; relative ERP 50.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 3 dB attenuation; relative ERP 50.1% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 1 dB attenuation; relative ERP 79.4% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 1 dB attenuation; relative ERP 79.4% of peak 280°: 2 dB attenuation; relative ERP 63.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 3 dB attenuation; relative ERP 50.1% of peak 320°: 3 dB attenuation; relative ERP 50.1% of peak 330°: 3 dB attenuation; relative ERP 50.1% of peak 340°: 2 dB attenuation; relative ERP 63.1% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260° at 0 dB attenuation.

Deepest restriction(s): 20°, 30°, 50°, 110°, 120°, 130°, 140°, 150°, 290°, 300°, 310°, 320°, 330° at 3 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 1.05 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 2 dB attenuation; relative ERP 63.1% of peak 10°: 2 dB attenuation; relative ERP 63.1% of peak 20°: 3 dB attenuation; relative ERP 50.1% of peak 30°: 3 dB attenuation; relative ERP 50.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 3 dB attenuation; relative ERP 50.1% of peak 60°: 2 dB attenuation; relative ERP 63.1% of peak 70°: 2 dB attenuation; relative ERP 63.1% of peak 80°: 2 dB attenuation; relative ERP 63.1% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 3 dB attenuation; relative ERP 50.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 3 dB attenuation; relative ERP 50.1% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 1 dB attenuation; relative ERP 79.4% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 1 dB attenuation; relative ERP 79.4% of peak 280°: 2 dB attenuation; relative ERP 63.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 3 dB attenuation; relative ERP 50.1% of peak 320°: 3 dB attenuation; relative ERP 50.1% of peak 330°: 3 dB attenuation; relative ERP 50.1% of peak 340°: 2 dB attenuation; relative ERP 63.1% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260° at 0 dB attenuation.

Deepest restriction(s): 20°, 30°, 50°, 110°, 120°, 130°, 140°, 150°, 290°, 300°, 310°, 320°, 330° at 3 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio Lancashire (FM)
Area Lancashire
Site Lancaster
Licence BBC000025
mb21 Lancaster
Frequency 104.5
NGR SD49086622
RDS PS BBC_Lanc
RDS PI CA13
Switched PI
TP/TA
TMC
Lat 54.089355
Long -2.779963
Site Ht 88
In-Use Aerial Ht 68
In-UseERP/HP 1.05 kW
In-Use ERP/VP 1.05 kW
Max Dir
Licensed ERP/HP 1 kW
Licensed ERP/VP 1 kW

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
223323222223333321000000000123333322

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
223323222223333321000000000123333322