Bluebell Hill (TV) - Ofcom TX Visualiser

← Back to DAB search · Map this site name · Offline SVG map

Bluebell Hill (TV)

North Kent · London 2 · 12A / 223.936 MHz

Antenna pattern

Antenna pattern

ERP field: In-Use ERP Total = 2 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 1 dB attenuation; relative ERP 79.4% of peak 30°: 2 dB attenuation; relative ERP 63.1% of peak 40°: 4 dB attenuation; relative ERP 39.8% of peak 50°: 7 dB attenuation; relative ERP 20% of peak 60°: 10 dB attenuation; relative ERP 10% of peak 70°: 15 dB attenuation; relative ERP 3.2% of peak 80°: 17 dB attenuation; relative ERP 2% of peak 90°: 20 dB attenuation; relative ERP 1% of peak 100°: 20 dB attenuation; relative ERP 1% of peak 110°: 20 dB attenuation; relative ERP 1% of peak 120°: 20 dB attenuation; relative ERP 1% of peak 130°: 20 dB attenuation; relative ERP 1% of peak 140°: 20 dB attenuation; relative ERP 1% of peak 150°: 20 dB attenuation; relative ERP 1% of peak 160°: 20 dB attenuation; relative ERP 1% of peak 170°: 20 dB attenuation; relative ERP 1% of peak 180°: 20 dB attenuation; relative ERP 1% of peak 190°: 17 dB attenuation; relative ERP 2% of peak 200°: 15 dB attenuation; relative ERP 3.2% of peak 210°: 10 dB attenuation; relative ERP 10% of peak 220°: 8 dB attenuation; relative ERP 15.8% of peak 230°: 4 dB attenuation; relative ERP 39.8% of peak 240°: 2 dB attenuation; relative ERP 63.1% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 1 dB attenuation; relative ERP 79.4% of peak 280°: 1 dB attenuation; relative ERP 79.4% of peak 290°: 2 dB attenuation; relative ERP 63.1% of peak 300°: 2 dB attenuation; relative ERP 63.1% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 3 dB attenuation; relative ERP 50.1% of peak 340°: 3 dB attenuation; relative ERP 50.1% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 310°, 320° at 0 dB attenuation.

Deepest restriction(s): 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180° at 20 dB attenuation.

Parameters

Date 14/11/2000
Ensemble London 2
Licence DL000011
mb21 Bluebell Hill (possible match)
Ensemble Area London
EID C186
Transmitter Area North Kent
Site Bluebell Hill (TV)
Freq. 223.936
Block 12A
TII Main Id (Hex) 0B
TII Sub Id (Hex) 04
NGR TQ75736134
Longitude/Latitude 000E31 14 51N19 26
Lat 51.324015
Long 0.520684
Site Height 192
In-Use Ae Ht 41
In-Use ERP Total 2 kW
Dir Max ERP 315°

Services listed for this ensemble row

TypeService labelSIdLSN
Audio Mi-Soul C7CD
Audio BBC Radio London CC31 77
Audio Nation London C8D9 1AC
Audio 88.3 CENTREFORCE C6E3
Audio Radio Maria Eng C9EA
Audio Virgin 80s C1EB 1F1
Audio Sunrise Retro CDDB
Audio Nation 80s C2EF
Audio Colourful C7EC
Audio ADVENTIST RADIO CBDE
Audio CountryLineRadio C2D4
Audio Virgin 90s C248
Audio Nation 70s C2ED
Audio Nation 90s C2FA
Audio NationClasHits C2FE
Audio Boom Lite C9C2
Audio Track Radio CC5C
Data Slideshow E1C000D1

Pattern values

Antenna pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
0012471015172020202020202020202017151084211112200331