Kendal - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Kendal

South Lakes · BBC Radio Cumbria (FM) · 95.2 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 14 dB attenuation; relative ERP 4% of peak 10°: 14 dB attenuation; relative ERP 4% of peak 20°: 14 dB attenuation; relative ERP 4% of peak 30°: 14 dB attenuation; relative ERP 4% of peak 40°: 14 dB attenuation; relative ERP 4% of peak 50°: 14 dB attenuation; relative ERP 4% of peak 60°: 14 dB attenuation; relative ERP 4% of peak 70°: 13 dB attenuation; relative ERP 5% of peak 80°: 11 dB attenuation; relative ERP 7.9% of peak 90°: 10 dB attenuation; relative ERP 10% of peak 100°: 10 dB attenuation; relative ERP 10% of peak 110°: 10 dB attenuation; relative ERP 10% of peak 120°: 11 dB attenuation; relative ERP 7.9% of peak 130°: 13 dB attenuation; relative ERP 5% of peak 140°: 14 dB attenuation; relative ERP 4% of peak 150°: 14 dB attenuation; relative ERP 4% of peak 160°: 14 dB attenuation; relative ERP 4% of peak 170°: 14 dB attenuation; relative ERP 4% of peak 180°: 14 dB attenuation; relative ERP 4% of peak 190°: 14 dB attenuation; relative ERP 4% of peak 200°: 14 dB attenuation; relative ERP 4% of peak 210°: 14 dB attenuation; relative ERP 4% of peak 220°: 10 dB attenuation; relative ERP 10% of peak 230°: 6 dB attenuation; relative ERP 25.1% of peak 240°: 3 dB attenuation; relative ERP 50.1% of peak 250°: 2 dB attenuation; relative ERP 63.1% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 1 dB attenuation; relative ERP 79.4% of peak 310°: 2 dB attenuation; relative ERP 63.1% of peak 320°: 3 dB attenuation; relative ERP 50.1% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 10 dB attenuation; relative ERP 10% of peak 350°: 14 dB attenuation; relative ERP 4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 270°, 280°, 290° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 350° at 14 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 3 dB attenuation; relative ERP 50.1% of peak 10°: 4 dB attenuation; relative ERP 39.8% of peak 20°: 6 dB attenuation; relative ERP 25.1% of peak 30°: 8 dB attenuation; relative ERP 15.8% of peak 40°: 9 dB attenuation; relative ERP 12.6% of peak 50°: 10 dB attenuation; relative ERP 10% of peak 60°: 11 dB attenuation; relative ERP 7.9% of peak 70°: 10 dB attenuation; relative ERP 10% of peak 80°: 10 dB attenuation; relative ERP 10% of peak 90°: 10 dB attenuation; relative ERP 10% of peak 100°: 10 dB attenuation; relative ERP 10% of peak 110°: 10 dB attenuation; relative ERP 10% of peak 120°: 10 dB attenuation; relative ERP 10% of peak 130°: 10 dB attenuation; relative ERP 10% of peak 140°: 11 dB attenuation; relative ERP 7.9% of peak 150°: 10 dB attenuation; relative ERP 10% of peak 160°: 9 dB attenuation; relative ERP 12.6% of peak 170°: 8 dB attenuation; relative ERP 15.8% of peak 180°: 6 dB attenuation; relative ERP 25.1% of peak 190°: 4 dB attenuation; relative ERP 39.8% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 1 dB attenuation; relative ERP 79.4% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 1 dB attenuation; relative ERP 79.4% of peak 330°: 1 dB attenuation; relative ERP 79.4% of peak 340°: 2 dB attenuation; relative ERP 63.1% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 250°, 260°, 270°, 280°, 290°, 300°, 310° at 0 dB attenuation.

Deepest restriction(s): 60°, 140° at 11 dB attenuation.

Parameters

Date 27/03/2009
Station BBC Radio Cumbria (FM)
Area South Lakes
Site Kendal
Licence BBC000017
mb21 Kendal
Frequency 95.2
NGR SD54039123
RDS PS BBC_Cmbr
RDS PI C817
Switched PI
TP/TA Y
TMC
Lat 54.314578
Long -2.708128
Site Ht 172
In-Use Aerial Ht 44
In-UseERP/HP 100 W
In-Use ERP/VP 100 W
Max Dir
Licensed ERP/HP 100 W
Licensed ERP/VP 100 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
1414141414141413111010101113141414141414141410632100012361014

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
34689101110101010101010111098643221100000001122