Moorside Edge - Ofcom TX Visualiser

← Back to AM/MF search · Map this site name · Offline SVG map

Moorside Edge

West Yorkshire · Talk Sport · 1089 kHz

Antenna pattern

In-use MF pattern

ERP field: In-Use EMRP (kW) = 400 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 4 dB attenuation; relative ERP 39.8% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 1 dB attenuation; relative ERP 79.4% of peak 40°: 1 dB attenuation; relative ERP 79.4% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 4 dB attenuation; relative ERP 39.8% of peak 130°: 7 dB attenuation; relative ERP 20% of peak 140°: 11 dB attenuation; relative ERP 7.9% of peak 150°: 20 dB attenuation; relative ERP 1% of peak 160°: 19 dB attenuation; relative ERP 1.3% of peak 170°: 10 dB attenuation; relative ERP 10% of peak 180°: 6 dB attenuation; relative ERP 25.1% of peak 190°: 4 dB attenuation; relative ERP 39.8% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 1 dB attenuation; relative ERP 79.4% of peak 280°: 2 dB attenuation; relative ERP 63.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 4 dB attenuation; relative ERP 39.8% of peak 310°: 7 dB attenuation; relative ERP 20% of peak 320°: 11 dB attenuation; relative ERP 7.9% of peak 330°: 20 dB attenuation; relative ERP 1% of peak 340°: 20 dB attenuation; relative ERP 1% of peak 350°: 10 dB attenuation; relative ERP 10% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 50°, 60°, 70°, 80°, 230°, 240°, 250°, 260° at 0 dB attenuation.

Deepest restriction(s): 150°, 330°, 340° at 20 dB attenuation.

Licensed MF pattern

ERP field: Licensed EMRP = 400 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 4 dB attenuation; relative ERP 39.8% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 1 dB attenuation; relative ERP 79.4% of peak 40°: 1 dB attenuation; relative ERP 79.4% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 4 dB attenuation; relative ERP 39.8% of peak 130°: 7 dB attenuation; relative ERP 20% of peak 140°: 11 dB attenuation; relative ERP 7.9% of peak 150°: 20 dB attenuation; relative ERP 1% of peak 160°: 19 dB attenuation; relative ERP 1.3% of peak 170°: 10 dB attenuation; relative ERP 10% of peak 180°: 6 dB attenuation; relative ERP 25.1% of peak 190°: 4 dB attenuation; relative ERP 39.8% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 1 dB attenuation; relative ERP 79.4% of peak 280°: 2 dB attenuation; relative ERP 63.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 4 dB attenuation; relative ERP 39.8% of peak 310°: 7 dB attenuation; relative ERP 20% of peak 320°: 11 dB attenuation; relative ERP 7.9% of peak 330°: 20 dB attenuation; relative ERP 1% of peak 340°: 20 dB attenuation; relative ERP 1% of peak 350°: 10 dB attenuation; relative ERP 10% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 50°, 60°, 70°, 80°, 230°, 240°, 250°, 260° at 0 dB attenuation.

Deepest restriction(s): 150°, 330°, 340° at 20 dB attenuation.

Parameters

Date 15/01/1995
Station Talk Sport
Area West Yorkshire
Site Moorside Edge
Licence AN000003
mb21 Moorside Edge
Frequency 1089
NGR SE07071542
Lat 53.635255
Long -1.894553
Site Ht 340
In-Use Aerial Ht 152
In-Use EMRP (kW) 400 kW
Max Dir
Licensed Aerial Ht 152
Licensed EMRP 400 kW

Pattern values

In-use MF pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
64211000012347112019106432100001234711202010

Licensed MF pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
64211000012347112019106432100001234711202010