Droitwich - Ofcom TX Visualiser

← Back to AM/MF search · Map this site name · Offline SVG map

Droitwich

Worcestershire · Talk Sport · 1053 kHz

Antenna pattern

In-use MF pattern

ERP field: In-Use EMRP (kW) = 500 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 1 dB attenuation; relative ERP 79.4% of peak 10°: 1 dB attenuation; relative ERP 79.4% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 4 dB attenuation; relative ERP 39.8% of peak 120°: 5 dB attenuation; relative ERP 31.6% of peak 130°: 6 dB attenuation; relative ERP 25.1% of peak 140°: 6 dB attenuation; relative ERP 25.1% of peak 150°: 7 dB attenuation; relative ERP 20% of peak 160°: 7 dB attenuation; relative ERP 20% of peak 170°: 8 dB attenuation; relative ERP 15.8% of peak 180°: 9 dB attenuation; relative ERP 12.6% of peak 190°: 10 dB attenuation; relative ERP 10% of peak 200°: 10 dB attenuation; relative ERP 10% of peak 210°: 10 dB attenuation; relative ERP 10% of peak 220°: 9 dB attenuation; relative ERP 12.6% of peak 230°: 9 dB attenuation; relative ERP 12.6% of peak 240°: 9 dB attenuation; relative ERP 12.6% of peak 250°: 9 dB attenuation; relative ERP 12.6% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 10 dB attenuation; relative ERP 10% of peak 280°: 10 dB attenuation; relative ERP 10% of peak 290°: 9 dB attenuation; relative ERP 12.6% of peak 300°: 8 dB attenuation; relative ERP 15.8% of peak 310°: 7 dB attenuation; relative ERP 20% of peak 320°: 5 dB attenuation; relative ERP 31.6% of peak 330°: 4 dB attenuation; relative ERP 39.8% of peak 340°: 3 dB attenuation; relative ERP 50.1% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 20°, 30°, 40°, 50°, 60° at 0 dB attenuation.

Deepest restriction(s): 190°, 200°, 210°, 260°, 270°, 280° at 10 dB attenuation.

Licensed MF pattern

ERP field: Licensed EMRP = 500 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 1 dB attenuation; relative ERP 79.4% of peak 10°: 1 dB attenuation; relative ERP 79.4% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 4 dB attenuation; relative ERP 39.8% of peak 120°: 5 dB attenuation; relative ERP 31.6% of peak 130°: 6 dB attenuation; relative ERP 25.1% of peak 140°: 6 dB attenuation; relative ERP 25.1% of peak 150°: 7 dB attenuation; relative ERP 20% of peak 160°: 7 dB attenuation; relative ERP 20% of peak 170°: 8 dB attenuation; relative ERP 15.8% of peak 180°: 9 dB attenuation; relative ERP 12.6% of peak 190°: 10 dB attenuation; relative ERP 10% of peak 200°: 10 dB attenuation; relative ERP 10% of peak 210°: 10 dB attenuation; relative ERP 10% of peak 220°: 9 dB attenuation; relative ERP 12.6% of peak 230°: 9 dB attenuation; relative ERP 12.6% of peak 240°: 9 dB attenuation; relative ERP 12.6% of peak 250°: 9 dB attenuation; relative ERP 12.6% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 10 dB attenuation; relative ERP 10% of peak 280°: 10 dB attenuation; relative ERP 10% of peak 290°: 9 dB attenuation; relative ERP 12.6% of peak 300°: 8 dB attenuation; relative ERP 15.8% of peak 310°: 7 dB attenuation; relative ERP 20% of peak 320°: 5 dB attenuation; relative ERP 31.6% of peak 330°: 4 dB attenuation; relative ERP 39.8% of peak 340°: 3 dB attenuation; relative ERP 50.1% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 20°, 30°, 40°, 50°, 60° at 0 dB attenuation.

Deepest restriction(s): 190°, 200°, 210°, 260°, 270°, 280° at 10 dB attenuation.

Parameters

Date 15/01/1995
Station Talk Sport
Area Worcestershire
Site Droitwich
Licence AN000003
mb21 Droitwich
Frequency 1053
NGR SO92916672
Lat 52.298558
Long -2.105388
Site Ht 48
In-Use Aerial Ht 100
In-Use EMRP (kW) 500 kW
Max Dir 40
Licensed Aerial Ht 100
Licensed EMRP 500 kW

Pattern values

In-use MF pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
110000011234566778910101099991010109875432

Licensed MF pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
110000011234566778910101099991010109875432