Stranraer - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Stranraer

Galloway · BBC Radio 4 (FM) · 103.6 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 31 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 12 dB attenuation; relative ERP 6.3% of peak 10°: 14 dB attenuation; relative ERP 4% of peak 20°: 14 dB attenuation; relative ERP 4% of peak 30°: 14 dB attenuation; relative ERP 4% of peak 40°: 14 dB attenuation; relative ERP 4% of peak 50°: 14 dB attenuation; relative ERP 4% of peak 60°: 14 dB attenuation; relative ERP 4% of peak 70°: 14 dB attenuation; relative ERP 4% of peak 80°: 14 dB attenuation; relative ERP 4% of peak 90°: 14 dB attenuation; relative ERP 4% of peak 100°: 14 dB attenuation; relative ERP 4% of peak 110°: 14 dB attenuation; relative ERP 4% of peak 120°: 14 dB attenuation; relative ERP 4% of peak 130°: 14 dB attenuation; relative ERP 4% of peak 140°: 12 dB attenuation; relative ERP 6.3% of peak 150°: 9 dB attenuation; relative ERP 12.6% of peak 160°: 6 dB attenuation; relative ERP 25.1% of peak 170°: 4 dB attenuation; relative ERP 39.8% of peak 180°: 2 dB attenuation; relative ERP 63.1% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 2 dB attenuation; relative ERP 63.1% of peak 280°: 2 dB attenuation; relative ERP 63.1% of peak 290°: 1 dB attenuation; relative ERP 79.4% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 1 dB attenuation; relative ERP 79.4% of peak 320°: 2 dB attenuation; relative ERP 63.1% of peak 330°: 3 dB attenuation; relative ERP 50.1% of peak 340°: 5 dB attenuation; relative ERP 31.6% of peak 350°: 7 dB attenuation; relative ERP 20% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 200°, 210°, 250°, 260°, 300° at 0 dB attenuation.

Deepest restriction(s): 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130° at 14 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 40 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 9 dB attenuation; relative ERP 12.6% of peak 20°: 12 dB attenuation; relative ERP 6.3% of peak 30°: 12 dB attenuation; relative ERP 6.3% of peak 40°: 12 dB attenuation; relative ERP 6.3% of peak 50°: 12 dB attenuation; relative ERP 6.3% of peak 60°: 12 dB attenuation; relative ERP 6.3% of peak 70°: 12 dB attenuation; relative ERP 6.3% of peak 80°: 12 dB attenuation; relative ERP 6.3% of peak 90°: 12 dB attenuation; relative ERP 6.3% of peak 100°: 12 dB attenuation; relative ERP 6.3% of peak 110°: 12 dB attenuation; relative ERP 6.3% of peak 120°: 12 dB attenuation; relative ERP 6.3% of peak 130°: 10 dB attenuation; relative ERP 10% of peak 140°: 7 dB attenuation; relative ERP 20% of peak 150°: 4 dB attenuation; relative ERP 39.8% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 0 dB attenuation.

Deepest restriction(s): 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120° at 12 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 40 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 9 dB attenuation; relative ERP 12.6% of peak 20°: 12 dB attenuation; relative ERP 6.3% of peak 30°: 12 dB attenuation; relative ERP 6.3% of peak 40°: 12 dB attenuation; relative ERP 6.3% of peak 50°: 12 dB attenuation; relative ERP 6.3% of peak 60°: 12 dB attenuation; relative ERP 6.3% of peak 70°: 12 dB attenuation; relative ERP 6.3% of peak 80°: 12 dB attenuation; relative ERP 6.3% of peak 90°: 12 dB attenuation; relative ERP 6.3% of peak 100°: 12 dB attenuation; relative ERP 6.3% of peak 110°: 12 dB attenuation; relative ERP 6.3% of peak 120°: 12 dB attenuation; relative ERP 6.3% of peak 130°: 10 dB attenuation; relative ERP 10% of peak 140°: 7 dB attenuation; relative ERP 20% of peak 150°: 4 dB attenuation; relative ERP 39.8% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 0 dB attenuation.

Deepest restriction(s): 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120° at 12 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio 4 (FM)
Area Galloway
Site Stranraer
Licence BBC000004
mb21 Stranraer
Frequency 103.6
NGR NX11146325
RDS PS _BBC_R4_
RDS PI C204
Switched PI
TP/TA
TMC
Lat 54.928096
Long -4.949005
Site Ht 190
In-Use Aerial Ht 35
In-UseERP/HP 0 W
In-Use ERP/VP 31 W
Max Dir
Licensed ERP/HP 40 W
Licensed ERP/VP 40 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
121414141414141414141414141412964210012100221012357

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
691212121212121212121212107410000000000000000002

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
691212121212121212121212107410000000000000000002