Langley Mill B

Birmingham · Radio XL · 1296 kHz

Antenna pattern

In-use MF pattern

ERP field: In-Use EMRP (kW) = 10 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 10 dB attenuation; relative ERP 10% of peak 10°: 11 dB attenuation; relative ERP 7.9% of peak 20°: 12 dB attenuation; relative ERP 6.3% of peak 30°: 15 dB attenuation; relative ERP 3.2% of peak 40°: 15 dB attenuation; relative ERP 3.2% of peak 50°: 20 dB attenuation; relative ERP 1% of peak 60°: 20 dB attenuation; relative ERP 1% of peak 70°: 20 dB attenuation; relative ERP 1% of peak 80°: 14 dB attenuation; relative ERP 4% of peak 90°: 10 dB attenuation; relative ERP 10% of peak 100°: 9 dB attenuation; relative ERP 12.6% of peak 110°: 9 dB attenuation; relative ERP 12.6% of peak 120°: 9 dB attenuation; relative ERP 12.6% of peak 130°: 8 dB attenuation; relative ERP 15.8% of peak 140°: 7 dB attenuation; relative ERP 20% of peak 150°: 4 dB attenuation; relative ERP 39.8% of peak 160°: 3 dB attenuation; relative ERP 50.1% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 2 dB attenuation; relative ERP 63.1% of peak 190°: 2 dB attenuation; relative ERP 63.1% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 1 dB attenuation; relative ERP 79.4% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 2 dB attenuation; relative ERP 63.1% of peak 280°: 2 dB attenuation; relative ERP 63.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 4 dB attenuation; relative ERP 39.8% of peak 310°: 7 dB attenuation; relative ERP 20% of peak 320°: 8 dB attenuation; relative ERP 15.8% of peak 330°: 8 dB attenuation; relative ERP 15.8% of peak 340°: 9 dB attenuation; relative ERP 12.6% of peak 350°: 9 dB attenuation; relative ERP 12.6% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 230°, 240° at 0 dB attenuation.

Deepest restriction(s): 50°, 60°, 70° at 20 dB attenuation.

Licensed MF pattern

ERP field: Licensed EMRP = 10 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 12 dB attenuation; relative ERP 6.3% of peak 10°: 14 dB attenuation; relative ERP 4% of peak 20°: 14 dB attenuation; relative ERP 4% of peak 30°: 15 dB attenuation; relative ERP 3.2% of peak 40°: 15 dB attenuation; relative ERP 3.2% of peak 50°: 15 dB attenuation; relative ERP 3.2% of peak 60°: 14 dB attenuation; relative ERP 4% of peak 70°: 14 dB attenuation; relative ERP 4% of peak 80°: 12 dB attenuation; relative ERP 6.3% of peak 90°: 10 dB attenuation; relative ERP 10% of peak 100°: 8 dB attenuation; relative ERP 15.8% of peak 110°: 6 dB attenuation; relative ERP 25.1% of peak 120°: 4 dB attenuation; relative ERP 39.8% of peak 130°: 3 dB attenuation; relative ERP 50.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 1 dB attenuation; relative ERP 79.4% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 1 dB attenuation; relative ERP 79.4% of peak 280°: 1 dB attenuation; relative ERP 79.4% of peak 290°: 2 dB attenuation; relative ERP 63.1% of peak 300°: 2 dB attenuation; relative ERP 63.1% of peak 310°: 3 dB attenuation; relative ERP 50.1% of peak 320°: 4 dB attenuation; relative ERP 39.8% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 8 dB attenuation; relative ERP 15.8% of peak 350°: 10 dB attenuation; relative ERP 10% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 190°, 200°, 210°, 220° at 0 dB attenuation.

Deepest restriction(s): 30°, 40°, 50° at 15 dB attenuation.

Parameters

Date 01/05/1995
Station Radio XL
Area Birmingham
Site Langley Mill B
Licence AL000171
mb21 Langley Mill (B)
MCA map Open Ofcom MCA map
Frequency 1296
NGR SP16159656
Lat 52.566631
Long -1.763169
Site Ht 96
In-Use Aerial Ht 50
In-Use EMRP (kW) 10 kW
Max Dir 235
Licensed Aerial Ht 50
Licensed EMRP 10 kW

Pattern values

In-use MF pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
1011121515202020141099987432222110011223478899

Licensed MF pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
12141415151514141210864332221000011111122346810