Stanton Moor - Ofcom TX Visualiser

← Back to DAB search · Map this site name · Offline SVG map

Stanton Moor

North Derbyshire · Derbyshire · 10B / 211.648 MHz

Antenna pattern

Antenna pattern

ERP field: In-Use ERP Total = 1.6 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0.6 dB attenuation; relative ERP 87.1% of peak 10°: 2.5 dB attenuation; relative ERP 56.2% of peak 20°: 7.4 dB attenuation; relative ERP 18.2% of peak 30°: 8.7 dB attenuation; relative ERP 13.5% of peak 40°: 11.1 dB attenuation; relative ERP 7.8% of peak 50°: 10.4 dB attenuation; relative ERP 9.1% of peak 60°: 10 dB attenuation; relative ERP 10% of peak 70°: 10.1 dB attenuation; relative ERP 9.8% of peak 80°: 3.8 dB attenuation; relative ERP 41.7% of peak 90°: 1.3 dB attenuation; relative ERP 74.1% of peak 100°: 1.5 dB attenuation; relative ERP 70.8% of peak 110°: 0.3 dB attenuation; relative ERP 93.3% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0.4 dB attenuation; relative ERP 91.2% of peak 140°: 0.8 dB attenuation; relative ERP 83.2% of peak 150°: 1.3 dB attenuation; relative ERP 74.1% of peak 160°: 2.6 dB attenuation; relative ERP 55% of peak 170°: 6.7 dB attenuation; relative ERP 21.4% of peak 180°: 7.2 dB attenuation; relative ERP 19.1% of peak 190°: 6.7 dB attenuation; relative ERP 21.4% of peak 200°: 17.1 dB attenuation; relative ERP 1.9% of peak 210°: 10.8 dB attenuation; relative ERP 8.3% of peak 220°: 16.8 dB attenuation; relative ERP 2.1% of peak 230°: 15.7 dB attenuation; relative ERP 2.7% of peak 240°: 12.1 dB attenuation; relative ERP 6.2% of peak 250°: 22.4 dB attenuation; relative ERP 0.6% of peak 260°: 9.8 dB attenuation; relative ERP 10.5% of peak 270°: 9.8 dB attenuation; relative ERP 10.5% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 2 dB attenuation; relative ERP 63.1% of peak 300°: 0.9 dB attenuation; relative ERP 81.3% of peak 310°: 0.4 dB attenuation; relative ERP 91.2% of peak 320°: 0.1 dB attenuation; relative ERP 97.7% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0.5 dB attenuation; relative ERP 89.1% of peak 350°: 1.3 dB attenuation; relative ERP 74.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 120°, 330° at 0 dB attenuation.

Deepest restriction(s): 250° at 22.4 dB attenuation.

Parameters

Date 15/12/2014
Ensemble Derbyshire
Licence DL000048
mb21 Stanton Moor
Ensemble Area Derbyshire
EID C1BD
Transmitter Area North Derbyshire
Site Stanton Moor
Freq. 211.648
Block 10B
TII Main Id (Hex) 20
TII Sub Id (Hex) 0D
NGR SK24586374
Longitude/Latitude 001W38 02 53N10 13
Lat 53.170211
Long -1.633756
Site Height 305
In-Use Ae Ht 43
In-Use ERP Total 1.6 kW
Dir Max ERP 330°

Services listed for this ensemble row

TypeService labelSIdLSN
Audio Capital C677 196 1AF 1C0 1C9
Audio Gold C9CE 19A
Audio HITS RADIO EMids C3AB
Audio BBC Radio Derby C937 29
Audio Smooth Radio C6A2 1B7 1B9 1D8
Audio Grt Hits E Mids C2E5 1E6 1E7
Audio Panjab Radio CED8
Audio Lyca Radio C142
Audio Nation 80s C2EF
Audio Nation 90s C2FA
Audio Heart Derby C954

Pattern values

Antenna pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
0.62.57.48.711.110.41010.13.81.31.50.300.40.81.32.66.77.26.717.110.816.815.712.122.49.89.8620.90.40.100.51.3