Holcombe Down - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Holcombe Down

Teignmouth · BBC Radio 4 (FM) · 93.8 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 1 dB attenuation; relative ERP 79.4% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 2 dB attenuation; relative ERP 63.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 4 dB attenuation; relative ERP 39.8% of peak 160°: 6 dB attenuation; relative ERP 25.1% of peak 170°: 7 dB attenuation; relative ERP 20% of peak 180°: 8 dB attenuation; relative ERP 15.8% of peak 190°: 10 dB attenuation; relative ERP 10% of peak 200°: 10 dB attenuation; relative ERP 10% of peak 210°: 10 dB attenuation; relative ERP 10% of peak 220°: 10 dB attenuation; relative ERP 10% of peak 230°: 10 dB attenuation; relative ERP 10% of peak 240°: 10 dB attenuation; relative ERP 10% of peak 250°: 10 dB attenuation; relative ERP 10% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 8 dB attenuation; relative ERP 15.8% of peak 280°: 7 dB attenuation; relative ERP 20% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 4 dB attenuation; relative ERP 39.8% of peak 310°: 3 dB attenuation; relative ERP 50.1% of peak 320°: 2 dB attenuation; relative ERP 63.1% of peak 330°: 2 dB attenuation; relative ERP 63.1% of peak 340°: 1 dB attenuation; relative ERP 79.4% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90° at 0 dB attenuation.

Deepest restriction(s): 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260° at 10 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 3 dB attenuation; relative ERP 50.1% of peak 180°: 3 dB attenuation; relative ERP 50.1% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 3 dB attenuation; relative ERP 50.1% of peak 230°: 3 dB attenuation; relative ERP 50.1% of peak 240°: 3 dB attenuation; relative ERP 50.1% of peak 250°: 3 dB attenuation; relative ERP 50.1% of peak 260°: 3 dB attenuation; relative ERP 50.1% of peak 270°: 3 dB attenuation; relative ERP 50.1% of peak 280°: 3 dB attenuation; relative ERP 50.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 2 dB attenuation; relative ERP 63.1% of peak 320°: 2 dB attenuation; relative ERP 63.1% of peak 330°: 1 dB attenuation; relative ERP 79.4% of peak 340°: 1 dB attenuation; relative ERP 79.4% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 350° at 0 dB attenuation.

Deepest restriction(s): 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300° at 3 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 3 dB attenuation; relative ERP 50.1% of peak 180°: 3 dB attenuation; relative ERP 50.1% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 3 dB attenuation; relative ERP 50.1% of peak 230°: 3 dB attenuation; relative ERP 50.1% of peak 240°: 3 dB attenuation; relative ERP 50.1% of peak 250°: 3 dB attenuation; relative ERP 50.1% of peak 260°: 3 dB attenuation; relative ERP 50.1% of peak 270°: 3 dB attenuation; relative ERP 50.1% of peak 280°: 3 dB attenuation; relative ERP 50.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 2 dB attenuation; relative ERP 63.1% of peak 320°: 2 dB attenuation; relative ERP 63.1% of peak 330°: 1 dB attenuation; relative ERP 79.4% of peak 340°: 1 dB attenuation; relative ERP 79.4% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 350° at 0 dB attenuation.

Deepest restriction(s): 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300° at 3 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio 4 (FM)
Area Teignmouth
Site Holcombe Down
Licence BBC000004
mb21 Holcombe Down
Frequency 93.8
NGR SX93417519
RDS PS _BBC_R4_
RDS PI C204
Switched PI
TP/TA
TMC
Lat 50.566705
Long -3.506408
Site Ht 205
In-Use Aerial Ht 25
In-UseERP/HP 0 W
In-Use ERP/VP 100 W
Max Dir
Licensed ERP/HP 100 W
Licensed ERP/VP 100 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
00000000001122346781010101010101010876432211

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000011223333333333333322110

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000011223333333333333322110