Beacon Hill North - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Beacon Hill North

Torbay · BBC Radio 1 · 98.4 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 794.3 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 3 dB attenuation; relative ERP 50.1% of peak 10°: 3 dB attenuation; relative ERP 50.1% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 1 dB attenuation; relative ERP 79.4% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 1 dB attenuation; relative ERP 79.4% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 3 dB attenuation; relative ERP 50.1% of peak 180°: 5 dB attenuation; relative ERP 31.6% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 7 dB attenuation; relative ERP 20% of peak 210°: 9 dB attenuation; relative ERP 12.6% of peak 220°: 13 dB attenuation; relative ERP 5% of peak 230°: 15 dB attenuation; relative ERP 3.2% of peak 240°: 17 dB attenuation; relative ERP 2% of peak 250°: 15 dB attenuation; relative ERP 3.2% of peak 260°: 15 dB attenuation; relative ERP 3.2% of peak 270°: 15 dB attenuation; relative ERP 3.2% of peak 280°: 15 dB attenuation; relative ERP 3.2% of peak 290°: 17 dB attenuation; relative ERP 2% of peak 300°: 17 dB attenuation; relative ERP 2% of peak 310°: 17 dB attenuation; relative ERP 2% of peak 320°: 15 dB attenuation; relative ERP 3.2% of peak 330°: 11 dB attenuation; relative ERP 7.9% of peak 340°: 9 dB attenuation; relative ERP 12.6% of peak 350°: 7 dB attenuation; relative ERP 20% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120° at 0 dB attenuation.

Deepest restriction(s): 240°, 290°, 300°, 310° at 17 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 1 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 4 dB attenuation; relative ERP 39.8% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 6 dB attenuation; relative ERP 25.1% of peak 210°: 6 dB attenuation; relative ERP 25.1% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 6 dB attenuation; relative ERP 25.1% of peak 240°: 6 dB attenuation; relative ERP 25.1% of peak 250°: 6 dB attenuation; relative ERP 25.1% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 6 dB attenuation; relative ERP 25.1% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 6 dB attenuation; relative ERP 25.1% of peak 310°: 6 dB attenuation; relative ERP 25.1% of peak 320°: 6 dB attenuation; relative ERP 25.1% of peak 330°: 4 dB attenuation; relative ERP 39.8% of peak 340°: 2 dB attenuation; relative ERP 63.1% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150° at 0 dB attenuation.

Deepest restriction(s): 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320° at 6 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 1 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 4 dB attenuation; relative ERP 39.8% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 6 dB attenuation; relative ERP 25.1% of peak 210°: 6 dB attenuation; relative ERP 25.1% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 6 dB attenuation; relative ERP 25.1% of peak 240°: 6 dB attenuation; relative ERP 25.1% of peak 250°: 6 dB attenuation; relative ERP 25.1% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 6 dB attenuation; relative ERP 25.1% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 6 dB attenuation; relative ERP 25.1% of peak 310°: 6 dB attenuation; relative ERP 25.1% of peak 320°: 6 dB attenuation; relative ERP 25.1% of peak 330°: 4 dB attenuation; relative ERP 39.8% of peak 340°: 2 dB attenuation; relative ERP 63.1% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150° at 0 dB attenuation.

Deepest restriction(s): 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320° at 6 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio 1
Area Torbay
Site Beacon Hill North
Licence BBC000001
Frequency 98.4
NGR SX85756205
RDS PS Radio_1_
RDS PI C201
Switched PI
TP/TA
TMC
Lat 50.447135
Long -3.610498
Site Ht 196
In-Use Aerial Ht 85
In-UseERP/HP 0 W
In-Use ERP/VP 794.3 W
Max Dir
Licensed ERP/HP 1 kW
Licensed ERP/VP 1 kW

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
332100000000011123567913151715151515171717151197

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000000012466666666666666421

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000000012466666666666666421