Basingstoke - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Basingstoke

Basingstoke · BBC Radio 1 · 99.7 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 20 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 2 dB attenuation; relative ERP 63.1% of peak 10°: 5 dB attenuation; relative ERP 31.6% of peak 20°: 9 dB attenuation; relative ERP 12.6% of peak 30°: 20 dB attenuation; relative ERP 1% of peak 40°: 20 dB attenuation; relative ERP 1% of peak 50°: 20 dB attenuation; relative ERP 1% of peak 60°: 20 dB attenuation; relative ERP 1% of peak 70°: 20 dB attenuation; relative ERP 1% of peak 80°: 20 dB attenuation; relative ERP 1% of peak 90°: 20 dB attenuation; relative ERP 1% of peak 100°: 20 dB attenuation; relative ERP 1% of peak 110°: 20 dB attenuation; relative ERP 1% of peak 120°: 20 dB attenuation; relative ERP 1% of peak 130°: 20 dB attenuation; relative ERP 1% of peak 140°: 20 dB attenuation; relative ERP 1% of peak 150°: 20 dB attenuation; relative ERP 1% of peak 160°: 20 dB attenuation; relative ERP 1% of peak 170°: 20 dB attenuation; relative ERP 1% of peak 180°: 20 dB attenuation; relative ERP 1% of peak 190°: 20 dB attenuation; relative ERP 1% of peak 200°: 20 dB attenuation; relative ERP 1% of peak 210°: 20 dB attenuation; relative ERP 1% of peak 220°: 20 dB attenuation; relative ERP 1% of peak 230°: 20 dB attenuation; relative ERP 1% of peak 240°: 20 dB attenuation; relative ERP 1% of peak 250°: 20 dB attenuation; relative ERP 1% of peak 260°: 20 dB attenuation; relative ERP 1% of peak 270°: 8 dB attenuation; relative ERP 15.8% of peak 280°: 4 dB attenuation; relative ERP 39.8% of peak 290°: 2 dB attenuation; relative ERP 63.1% of peak 300°: 1 dB attenuation; relative ERP 79.4% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 310°, 320°, 330°, 340° at 0 dB attenuation.

Deepest restriction(s): 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260° at 20 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 20 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 3 dB attenuation; relative ERP 50.1% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 6 dB attenuation; relative ERP 25.1% of peak 100°: 6 dB attenuation; relative ERP 25.1% of peak 110°: 6 dB attenuation; relative ERP 25.1% of peak 120°: 6 dB attenuation; relative ERP 25.1% of peak 130°: 6 dB attenuation; relative ERP 25.1% of peak 140°: 6 dB attenuation; relative ERP 25.1% of peak 150°: 6 dB attenuation; relative ERP 25.1% of peak 160°: 6 dB attenuation; relative ERP 25.1% of peak 170°: 6 dB attenuation; relative ERP 25.1% of peak 180°: 6 dB attenuation; relative ERP 25.1% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190° at 6 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 20 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 3 dB attenuation; relative ERP 50.1% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 6 dB attenuation; relative ERP 25.1% of peak 100°: 6 dB attenuation; relative ERP 25.1% of peak 110°: 6 dB attenuation; relative ERP 25.1% of peak 120°: 6 dB attenuation; relative ERP 25.1% of peak 130°: 6 dB attenuation; relative ERP 25.1% of peak 140°: 6 dB attenuation; relative ERP 25.1% of peak 150°: 6 dB attenuation; relative ERP 25.1% of peak 160°: 6 dB attenuation; relative ERP 25.1% of peak 170°: 6 dB attenuation; relative ERP 25.1% of peak 180°: 6 dB attenuation; relative ERP 25.1% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190° at 6 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio 1
Area Basingstoke
Site Basingstoke
Licence BBC000001
mb21 Basingstoke
Frequency 99.7
NGR SU64314792
RDS PS Radio_1_
RDS PI C201
Switched PI
TP/TA
TMC
Lat 51.226857
Long -1.080409
Site Ht 176
In-Use Aerial Ht 20
In-UseERP/HP 0 W
In-Use ERP/VP 20 W
Max Dir 325
Licensed ERP/HP 20 W
Licensed ERP/VP 20 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
259202020202020202020202020202020202020202020202020842100001

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000033666666666663300000000000000

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000033666666666663300000000000000