Brookmans Park - Ofcom TX Visualiser

← Back to AM/MF search · Map this site name · Offline SVG map

Brookmans Park

London · Lyca Radio 1458 · 1458 kHz

Antenna pattern

In-use MF pattern

ERP field: In-Use EMRP (kW) = 125 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 10 dB attenuation; relative ERP 10% of peak 10°: 12 dB attenuation; relative ERP 6.3% of peak 20°: 14 dB attenuation; relative ERP 4% of peak 30°: 14 dB attenuation; relative ERP 4% of peak 40°: 12 dB attenuation; relative ERP 6.3% of peak 50°: 9 dB attenuation; relative ERP 12.6% of peak 60°: 6 dB attenuation; relative ERP 25.1% of peak 70°: 4 dB attenuation; relative ERP 39.8% of peak 80°: 2 dB attenuation; relative ERP 63.1% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 3 dB attenuation; relative ERP 50.1% of peak 250°: 4 dB attenuation; relative ERP 39.8% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 10 dB attenuation; relative ERP 10% of peak 280°: 13 dB attenuation; relative ERP 5% of peak 290°: 14 dB attenuation; relative ERP 4% of peak 300°: 13 dB attenuation; relative ERP 5% of peak 310°: 11 dB attenuation; relative ERP 7.9% of peak 320°: 10 dB attenuation; relative ERP 10% of peak 330°: 9 dB attenuation; relative ERP 12.6% of peak 340°: 9 dB attenuation; relative ERP 12.6% of peak 350°: 9 dB attenuation; relative ERP 12.6% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210° at 0 dB attenuation.

Deepest restriction(s): 20°, 30°, 290° at 14 dB attenuation.

Licensed MF pattern

ERP field: Licensed EMRP = 125 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 10 dB attenuation; relative ERP 10% of peak 10°: 12 dB attenuation; relative ERP 6.3% of peak 20°: 14 dB attenuation; relative ERP 4% of peak 30°: 14 dB attenuation; relative ERP 4% of peak 40°: 12 dB attenuation; relative ERP 6.3% of peak 50°: 9 dB attenuation; relative ERP 12.6% of peak 60°: 6 dB attenuation; relative ERP 25.1% of peak 70°: 4 dB attenuation; relative ERP 39.8% of peak 80°: 2 dB attenuation; relative ERP 63.1% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 3 dB attenuation; relative ERP 50.1% of peak 250°: 4 dB attenuation; relative ERP 39.8% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 10 dB attenuation; relative ERP 10% of peak 280°: 13 dB attenuation; relative ERP 5% of peak 290°: 14 dB attenuation; relative ERP 4% of peak 300°: 13 dB attenuation; relative ERP 5% of peak 310°: 11 dB attenuation; relative ERP 7.9% of peak 320°: 10 dB attenuation; relative ERP 10% of peak 330°: 9 dB attenuation; relative ERP 12.6% of peak 340°: 9 dB attenuation; relative ERP 12.6% of peak 350°: 9 dB attenuation; relative ERP 12.6% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210° at 0 dB attenuation.

Deepest restriction(s): 20°, 30°, 290° at 14 dB attenuation.

Parameters

Date 01/01/1994
Station Lyca Radio 1458
Area London
Site Brookmans Park
Licence AL000156
mb21 Brookmans Park
MCA map Open Ofcom MCA map
Frequency 1458
NGR TL26040481
Lat 51.727848
Long -0.176463
Site Ht 127
In-Use Aerial Ht 76
In-Use EMRP (kW) 125 kW
Max Dir 155
Licensed Aerial Ht 76
Licensed EMRP 125 kW

Pattern values

In-use MF pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
10121414129642100000000000012346101314131110999

Licensed MF pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
10121414129642100000000000012346101314131110999