In-use MF pattern
ERP field: In-Use EMRP (kW) = 5 kW
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 16 dB attenuation; relative ERP 2.5% of peak
10°: 13 dB attenuation; relative ERP 5% of peak
20°: 11 dB attenuation; relative ERP 7.9% of peak
30°: 9 dB attenuation; relative ERP 12.6% of peak
40°: 9 dB attenuation; relative ERP 12.6% of peak
50°: 10 dB attenuation; relative ERP 10% of peak
60°: 12 dB attenuation; relative ERP 6.3% of peak
70°: 15 dB attenuation; relative ERP 3.2% of peak
80°: 20 dB attenuation; relative ERP 1% of peak
90°: 28 dB attenuation; relative ERP 0.2% of peak
100°: 30 dB attenuation; relative ERP 0.1% of peak
110°: 30 dB attenuation; relative ERP 0.1% of peak
120°: 30 dB attenuation; relative ERP 0.1% of peak
130°: 30 dB attenuation; relative ERP 0.1% of peak
140°: 20 dB attenuation; relative ERP 1% of peak
150°: 13 dB attenuation; relative ERP 5% of peak
160°: 6 dB attenuation; relative ERP 25.1% of peak
170°: 4 dB attenuation; relative ERP 39.8% of peak
180°: 2 dB attenuation; relative ERP 63.1% of peak
190°: 1 dB attenuation; relative ERP 79.4% of peak
200°: 0 dB attenuation; relative ERP 100% of peak
210°: 0 dB attenuation; relative ERP 100% of peak
220°: 0 dB attenuation; relative ERP 100% of peak
230°: 0 dB attenuation; relative ERP 100% of peak
240°: 1 dB attenuation; relative ERP 79.4% of peak
250°: 2 dB attenuation; relative ERP 63.1% of peak
260°: 4 dB attenuation; relative ERP 39.8% of peak
270°: 8 dB attenuation; relative ERP 15.8% of peak
280°: 14 dB attenuation; relative ERP 4% of peak
290°: 30 dB attenuation; relative ERP 0.1% of peak
300°: 30 dB attenuation; relative ERP 0.1% of peak
310°: 30 dB attenuation; relative ERP 0.1% of peak
320°: 30 dB attenuation; relative ERP 0.1% of peak
330°: 30 dB attenuation; relative ERP 0.1% of peak
340°: 30 dB attenuation; relative ERP 0.1% of peak
350°: 22 dB attenuation; relative ERP 0.6% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 200°, 210°, 220°, 230° at 0 dB attenuation.
Deepest restriction(s): 100°, 110°, 120°, 130°, 290°, 300°, 310°, 320°, 330°, 340° at 30 dB attenuation.
Licensed MF pattern
ERP field: Licensed EMRP = 28 kW
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 25 dB attenuation; relative ERP 0.3% of peak
10°: 18 dB attenuation; relative ERP 1.6% of peak
20°: 14 dB attenuation; relative ERP 4% of peak
30°: 13 dB attenuation; relative ERP 5% of peak
40°: 13 dB attenuation; relative ERP 5% of peak
50°: 14 dB attenuation; relative ERP 4% of peak
60°: 18 dB attenuation; relative ERP 1.6% of peak
70°: 25 dB attenuation; relative ERP 0.3% of peak
80°: 31 dB attenuation; relative ERP 0.1% of peak
90°: 28 dB attenuation; relative ERP 0.2% of peak
100°: 31 dB attenuation; relative ERP 0.1% of peak
110°: 31 dB attenuation; relative ERP 0.1% of peak
120°: 30 dB attenuation; relative ERP 0.1% of peak
130°: 31 dB attenuation; relative ERP 0.1% of peak
140°: 18 dB attenuation; relative ERP 1.6% of peak
150°: 9 dB attenuation; relative ERP 12.6% of peak
160°: 7 dB attenuation; relative ERP 20% of peak
170°: 3 dB attenuation; relative ERP 50.1% of peak
180°: 2 dB attenuation; relative ERP 63.1% of peak
190°: 1 dB attenuation; relative ERP 79.4% of peak
200°: 1 dB attenuation; relative ERP 79.4% of peak
210°: 0 dB attenuation; relative ERP 100% of peak
220°: 0 dB attenuation; relative ERP 100% of peak
230°: 1 dB attenuation; relative ERP 79.4% of peak
240°: 1 dB attenuation; relative ERP 79.4% of peak
250°: 2 dB attenuation; relative ERP 63.1% of peak
260°: 3 dB attenuation; relative ERP 50.1% of peak
270°: 7 dB attenuation; relative ERP 20% of peak
280°: 9 dB attenuation; relative ERP 12.6% of peak
290°: 16 dB attenuation; relative ERP 2.5% of peak
300°: 31 dB attenuation; relative ERP 0.1% of peak
310°: 30 dB attenuation; relative ERP 0.1% of peak
320°: 31 dB attenuation; relative ERP 0.1% of peak
330°: 30 dB attenuation; relative ERP 0.1% of peak
340°: 28 dB attenuation; relative ERP 0.2% of peak
350°: 31 dB attenuation; relative ERP 0.1% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 210°, 220° at 0 dB attenuation.
Deepest restriction(s): 80°, 100°, 110°, 130°, 300°, 320°, 350° at 31 dB attenuation.