Fenham - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Fenham

Newcastle · BBC Radio 3 · 92 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 42 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 14 dB attenuation; relative ERP 4% of peak 10°: 14 dB attenuation; relative ERP 4% of peak 20°: 14 dB attenuation; relative ERP 4% of peak 30°: 14 dB attenuation; relative ERP 4% of peak 40°: 14 dB attenuation; relative ERP 4% of peak 50°: 14 dB attenuation; relative ERP 4% of peak 60°: 14 dB attenuation; relative ERP 4% of peak 70°: 10 dB attenuation; relative ERP 10% of peak 80°: 7 dB attenuation; relative ERP 20% of peak 90°: 6 dB attenuation; relative ERP 25.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 1 dB attenuation; relative ERP 79.4% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 1 dB attenuation; relative ERP 79.4% of peak 210°: 1 dB attenuation; relative ERP 79.4% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 1 dB attenuation; relative ERP 79.4% of peak 290°: 1 dB attenuation; relative ERP 79.4% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 6 dB attenuation; relative ERP 25.1% of peak 320°: 7 dB attenuation; relative ERP 20% of peak 330°: 10 dB attenuation; relative ERP 10% of peak 340°: 14 dB attenuation; relative ERP 4% of peak 350°: 14 dB attenuation; relative ERP 4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 220°, 230°, 240°, 250°, 260°, 270° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 340°, 350° at 14 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Radio 3
Area Newcastle
Site Fenham
Licence BBC000003
mb21 Fenham
Frequency 92
NGR NZ21676488
RDS PS _BBC_R3_
RDS PI C203
Switched PI
TP/TA
TMC
Lat 54.978061
Long -1.662966
Site Ht 120
In-Use Aerial Ht 43
In-UseERP/HP 0 W
In-Use ERP/VP 42 W
Max Dir
Licensed ERP/HP 50 W
Licensed ERP/VP 50 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
14141414141414107631000000001100000011367101414