Belmont - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Belmont

Lincolnshire · BBC Lincolnshire (FM) · 94.9 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 3 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 10 dB attenuation; relative ERP 10% of peak 10°: 8 dB attenuation; relative ERP 15.8% of peak 20°: 11 dB attenuation; relative ERP 7.9% of peak 30°: 12 dB attenuation; relative ERP 6.3% of peak 40°: 8 dB attenuation; relative ERP 15.8% of peak 50°: 5 dB attenuation; relative ERP 31.6% of peak 60°: 5 dB attenuation; relative ERP 31.6% of peak 70°: 6 dB attenuation; relative ERP 25.1% of peak 80°: 8 dB attenuation; relative ERP 15.8% of peak 90°: 7 dB attenuation; relative ERP 20% of peak 100°: 6 dB attenuation; relative ERP 25.1% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 1 dB attenuation; relative ERP 79.4% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 3 dB attenuation; relative ERP 50.1% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 1 dB attenuation; relative ERP 79.4% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 3 dB attenuation; relative ERP 50.1% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 3 dB attenuation; relative ERP 50.1% of peak 280°: 5 dB attenuation; relative ERP 31.6% of peak 290°: 8 dB attenuation; relative ERP 15.8% of peak 300°: 8 dB attenuation; relative ERP 15.8% of peak 310°: 7 dB attenuation; relative ERP 20% of peak 320°: 5 dB attenuation; relative ERP 31.6% of peak 330°: 4 dB attenuation; relative ERP 39.8% of peak 340°: 7 dB attenuation; relative ERP 20% of peak 350°: 11 dB attenuation; relative ERP 7.9% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 190° at 0 dB attenuation.

Deepest restriction(s): 30° at 12 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 3 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 15 dB attenuation; relative ERP 3.2% of peak 10°: 14 dB attenuation; relative ERP 4% of peak 20°: 15 dB attenuation; relative ERP 3.2% of peak 30°: 20 dB attenuation; relative ERP 1% of peak 40°: 17 dB attenuation; relative ERP 2% of peak 50°: 15 dB attenuation; relative ERP 3.2% of peak 60°: 12 dB attenuation; relative ERP 6.3% of peak 70°: 9 dB attenuation; relative ERP 12.6% of peak 80°: 7 dB attenuation; relative ERP 20% of peak 90°: 5 dB attenuation; relative ERP 31.6% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 1 dB attenuation; relative ERP 79.4% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 1 dB attenuation; relative ERP 79.4% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 1 dB attenuation; relative ERP 79.4% of peak 210°: 1 dB attenuation; relative ERP 79.4% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 2 dB attenuation; relative ERP 63.1% of peak 280°: 3 dB attenuation; relative ERP 50.1% of peak 290°: 5 dB attenuation; relative ERP 31.6% of peak 300°: 7 dB attenuation; relative ERP 20% of peak 310°: 9 dB attenuation; relative ERP 12.6% of peak 320°: 12 dB attenuation; relative ERP 6.3% of peak 330°: 14 dB attenuation; relative ERP 4% of peak 340°: 15 dB attenuation; relative ERP 3.2% of peak 350°: 17 dB attenuation; relative ERP 2% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 130°, 140°, 150°, 160°, 220°, 230°, 240°, 250° at 0 dB attenuation.

Deepest restriction(s): 30° at 20 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 3.24 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 10 dB attenuation; relative ERP 10% of peak 10°: 7 dB attenuation; relative ERP 20% of peak 20°: 11 dB attenuation; relative ERP 7.9% of peak 30°: 10 dB attenuation; relative ERP 10% of peak 40°: 6 dB attenuation; relative ERP 25.1% of peak 50°: 4 dB attenuation; relative ERP 39.8% of peak 60°: 5 dB attenuation; relative ERP 31.6% of peak 70°: 7 dB attenuation; relative ERP 20% of peak 80°: 8 dB attenuation; relative ERP 15.8% of peak 90°: 7 dB attenuation; relative ERP 20% of peak 100°: 4 dB attenuation; relative ERP 39.8% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 1 dB attenuation; relative ERP 79.4% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 1 dB attenuation; relative ERP 79.4% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 3 dB attenuation; relative ERP 50.1% of peak 280°: 4 dB attenuation; relative ERP 39.8% of peak 290°: 8 dB attenuation; relative ERP 15.8% of peak 300°: 8 dB attenuation; relative ERP 15.8% of peak 310°: 6 dB attenuation; relative ERP 25.1% of peak 320°: 4 dB attenuation; relative ERP 39.8% of peak 330°: 5 dB attenuation; relative ERP 31.6% of peak 340°: 7 dB attenuation; relative ERP 20% of peak 350°: 11 dB attenuation; relative ERP 7.9% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 190° at 0 dB attenuation.

Deepest restriction(s): 20°, 350° at 11 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 3.24 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 10 dB attenuation; relative ERP 10% of peak 10°: 7 dB attenuation; relative ERP 20% of peak 20°: 11 dB attenuation; relative ERP 7.9% of peak 30°: 10 dB attenuation; relative ERP 10% of peak 40°: 6 dB attenuation; relative ERP 25.1% of peak 50°: 4 dB attenuation; relative ERP 39.8% of peak 60°: 5 dB attenuation; relative ERP 31.6% of peak 70°: 7 dB attenuation; relative ERP 20% of peak 80°: 8 dB attenuation; relative ERP 15.8% of peak 90°: 7 dB attenuation; relative ERP 20% of peak 100°: 4 dB attenuation; relative ERP 39.8% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 1 dB attenuation; relative ERP 79.4% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 1 dB attenuation; relative ERP 79.4% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 3 dB attenuation; relative ERP 50.1% of peak 280°: 4 dB attenuation; relative ERP 39.8% of peak 290°: 8 dB attenuation; relative ERP 15.8% of peak 300°: 8 dB attenuation; relative ERP 15.8% of peak 310°: 6 dB attenuation; relative ERP 25.1% of peak 320°: 4 dB attenuation; relative ERP 39.8% of peak 330°: 5 dB attenuation; relative ERP 31.6% of peak 340°: 7 dB attenuation; relative ERP 20% of peak 350°: 11 dB attenuation; relative ERP 7.9% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 190° at 0 dB attenuation.

Deepest restriction(s): 20°, 350° at 11 dB attenuation.

Parameters

Date 01/01/1900
Station BBC Lincolnshire (FM)
Area Lincolnshire
Site Belmont
Licence BBC000028
mb21 Belmont
Frequency 94.9
NGR TF21828366
RDS PS BBCLincs
RDS PI CB13
Switched PI
TP/TA
TMC
Lat 53.335831
Long -0.171982
Site Ht 125
In-Use Aerial Ht 196
In-UseERP/HP 3 kW
In-Use ERP/VP 3 kW
Max Dir
Licensed ERP/HP 3.24 kW
Licensed ERP/VP 3.24 kW

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
1081112855687631112321012321113588754711

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
15141520171512975321000011111000012357912141517

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
1071110645787421112221012221113488645711

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
1071110645787421112221012221113488645711