In-use horizontal pattern
ERP field: In-UseERP/HP = 1 kW
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 1 dB attenuation; relative ERP 79.4% of peak
10°: 2 dB attenuation; relative ERP 63.1% of peak
20°: 1 dB attenuation; relative ERP 79.4% of peak
30°: 0 dB attenuation; relative ERP 100% of peak
40°: 0 dB attenuation; relative ERP 100% of peak
50°: 1 dB attenuation; relative ERP 79.4% of peak
60°: 2 dB attenuation; relative ERP 63.1% of peak
70°: 2 dB attenuation; relative ERP 63.1% of peak
80°: 2 dB attenuation; relative ERP 63.1% of peak
90°: 2 dB attenuation; relative ERP 63.1% of peak
100°: 3 dB attenuation; relative ERP 50.1% of peak
110°: 2 dB attenuation; relative ERP 63.1% of peak
120°: 1 dB attenuation; relative ERP 79.4% of peak
130°: 0 dB attenuation; relative ERP 100% of peak
140°: 1 dB attenuation; relative ERP 79.4% of peak
150°: 2 dB attenuation; relative ERP 63.1% of peak
160°: 2 dB attenuation; relative ERP 63.1% of peak
170°: 1 dB attenuation; relative ERP 79.4% of peak
180°: 1 dB attenuation; relative ERP 79.4% of peak
190°: 1 dB attenuation; relative ERP 79.4% of peak
200°: 2 dB attenuation; relative ERP 63.1% of peak
210°: 4 dB attenuation; relative ERP 39.8% of peak
220°: 6 dB attenuation; relative ERP 25.1% of peak
230°: 9 dB attenuation; relative ERP 12.6% of peak
240°: 12 dB attenuation; relative ERP 6.3% of peak
250°: 15 dB attenuation; relative ERP 3.2% of peak
260°: 14 dB attenuation; relative ERP 4% of peak
270°: 13 dB attenuation; relative ERP 5% of peak
280°: 12 dB attenuation; relative ERP 6.3% of peak
290°: 11 dB attenuation; relative ERP 7.9% of peak
300°: 7 dB attenuation; relative ERP 20% of peak
310°: 4 dB attenuation; relative ERP 39.8% of peak
320°: 2 dB attenuation; relative ERP 63.1% of peak
330°: 1 dB attenuation; relative ERP 79.4% of peak
340°: 0 dB attenuation; relative ERP 100% of peak
350°: 0 dB attenuation; relative ERP 100% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 30°, 40°, 130°, 340°, 350° at 0 dB attenuation.
Deepest restriction(s): 250° at 15 dB attenuation.
In-use vertical pattern
ERP field: In-Use ERP/VP = 1 kW
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 0 dB attenuation; relative ERP 100% of peak
10°: 2 dB attenuation; relative ERP 63.1% of peak
20°: 4 dB attenuation; relative ERP 39.8% of peak
30°: 5 dB attenuation; relative ERP 31.6% of peak
40°: 3 dB attenuation; relative ERP 50.1% of peak
50°: 3 dB attenuation; relative ERP 50.1% of peak
60°: 4 dB attenuation; relative ERP 39.8% of peak
70°: 3 dB attenuation; relative ERP 50.1% of peak
80°: 1 dB attenuation; relative ERP 79.4% of peak
90°: 1 dB attenuation; relative ERP 79.4% of peak
100°: 3 dB attenuation; relative ERP 50.1% of peak
110°: 5 dB attenuation; relative ERP 31.6% of peak
120°: 5 dB attenuation; relative ERP 31.6% of peak
130°: 4 dB attenuation; relative ERP 39.8% of peak
140°: 4 dB attenuation; relative ERP 39.8% of peak
150°: 6 dB attenuation; relative ERP 25.1% of peak
160°: 3 dB attenuation; relative ERP 50.1% of peak
170°: 2 dB attenuation; relative ERP 63.1% of peak
180°: 1 dB attenuation; relative ERP 79.4% of peak
190°: 2 dB attenuation; relative ERP 63.1% of peak
200°: 4 dB attenuation; relative ERP 39.8% of peak
210°: 7 dB attenuation; relative ERP 20% of peak
220°: 10 dB attenuation; relative ERP 10% of peak
230°: 12 dB attenuation; relative ERP 6.3% of peak
240°: 16 dB attenuation; relative ERP 2.5% of peak
250°: 23 dB attenuation; relative ERP 0.5% of peak
260°: 26 dB attenuation; relative ERP 0.3% of peak
270°: 24 dB attenuation; relative ERP 0.4% of peak
280°: 19 dB attenuation; relative ERP 1.3% of peak
290°: 16 dB attenuation; relative ERP 2.5% of peak
300°: 12 dB attenuation; relative ERP 6.3% of peak
310°: 10 dB attenuation; relative ERP 10% of peak
320°: 7 dB attenuation; relative ERP 20% of peak
330°: 4 dB attenuation; relative ERP 39.8% of peak
340°: 1 dB attenuation; relative ERP 79.4% of peak
350°: 0 dB attenuation; relative ERP 100% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 0°, 350° at 0 dB attenuation.