Old Bolingbroke - Highfield Farm - Ofcom TX Visualiser

← Back to DAB search · Map this site name · Offline SVG map

Old Bolingbroke - Highfield Farm

Boston and Skegness · Boston, Spalding and Skegness small-scale · 8B / 197.648 MHz

Antenna pattern

Antenna pattern

ERP field: In-Use ERP Total = 2.5 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0.67 dB attenuation; relative ERP 85.7% of peak 10°: 0.36 dB attenuation; relative ERP 92% of peak 20°: 0.15 dB attenuation; relative ERP 96.6% of peak 30°: 0.03 dB attenuation; relative ERP 99.3% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0.05 dB attenuation; relative ERP 98.9% of peak 60°: 0.18 dB attenuation; relative ERP 95.9% of peak 70°: 0.41 dB attenuation; relative ERP 91% of peak 80°: 0.74 dB attenuation; relative ERP 84.3% of peak 90°: 1.19 dB attenuation; relative ERP 76% of peak 100°: 1.75 dB attenuation; relative ERP 66.8% of peak 110°: 2.45 dB attenuation; relative ERP 56.9% of peak 120°: 3.28 dB attenuation; relative ERP 47% of peak 130°: 4.22 dB attenuation; relative ERP 37.8% of peak 140°: 5.25 dB attenuation; relative ERP 29.9% of peak 150°: 6.3 dB attenuation; relative ERP 23.4% of peak 160°: 7.25 dB attenuation; relative ERP 18.8% of peak 170°: 8 dB attenuation; relative ERP 15.8% of peak 180°: 8.46 dB attenuation; relative ERP 14.3% of peak 190°: 8.66 dB attenuation; relative ERP 13.6% of peak 200°: 8.7 dB attenuation; relative ERP 13.5% of peak 210°: 8.67 dB attenuation; relative ERP 13.6% of peak 220°: 8.66 dB attenuation; relative ERP 13.6% of peak 230°: 8.68 dB attenuation; relative ERP 13.6% of peak 240°: 8.7 dB attenuation; relative ERP 13.5% of peak 250°: 8.64 dB attenuation; relative ERP 13.7% of peak 260°: 8.39 dB attenuation; relative ERP 14.5% of peak 270°: 7.87 dB attenuation; relative ERP 16.3% of peak 280°: 7.07 dB attenuation; relative ERP 19.6% of peak 290°: 6.09 dB attenuation; relative ERP 24.6% of peak 300°: 5.04 dB attenuation; relative ERP 31.3% of peak 310°: 4.03 dB attenuation; relative ERP 39.5% of peak 320°: 3.1 dB attenuation; relative ERP 49% of peak 330°: 2.3 dB attenuation; relative ERP 58.9% of peak 340°: 1.63 dB attenuation; relative ERP 68.7% of peak 350°: 1.09 dB attenuation; relative ERP 77.8% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 40° at 0 dB attenuation.

Deepest restriction(s): 200°, 240° at 8.7 dB attenuation.

Parameters

Date 05/12/2024
Ensemble Boston, Spalding and Skegness small-scale
Licence DS104800
Ensemble Area Boston, Spalding and Skegness
EID C21E
Transmitter Area Boston and Skegness
Site Old Bolingbroke - Highfield Farm
Freq. 197.648
Block 8B
TII Main Id (Hex) 32
TII Sub Id (Hex) 0C
NGR TF35626567
Longitude/Latitude 000E01 39 53N10 15
Lat 53.170871
Long 0.027472
Site Height 87
In-Use Ae Ht 25
In-Use ERP Total 2.5 kW
Dir Max ERP

Services listed for this ensemble row

TypeService labelSIdLSN
Audio East Lincs DAB C550
Audio 107 Endeavour FM C75E

Pattern values

Antenna pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
0.670.360.150.0300.050.180.410.741.191.752.453.284.225.256.37.2588.468.668.78.678.668.688.78.648.397.877.076.095.044.033.12.31.631.09