Minehead North - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Minehead North

Minehead · West Somerset Radio · 104.4 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 50.2 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 9 dB attenuation; relative ERP 12.6% of peak 10°: 12 dB attenuation; relative ERP 6.3% of peak 20°: 14 dB attenuation; relative ERP 4% of peak 30°: 18 dB attenuation; relative ERP 1.6% of peak 40°: 19 dB attenuation; relative ERP 1.3% of peak 50°: 14 dB attenuation; relative ERP 4% of peak 60°: 12 dB attenuation; relative ERP 6.3% of peak 70°: 9 dB attenuation; relative ERP 12.6% of peak 80°: 7.5 dB attenuation; relative ERP 17.8% of peak 90°: 6 dB attenuation; relative ERP 25.1% of peak 100°: 5 dB attenuation; relative ERP 31.6% of peak 110°: 4 dB attenuation; relative ERP 39.8% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 2 dB attenuation; relative ERP 63.1% of peak 140°: 1.5 dB attenuation; relative ERP 70.8% of peak 150°: 1 dB attenuation; relative ERP 79.4% of peak 160°: 0.5 dB attenuation; relative ERP 89.1% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0.2 dB attenuation; relative ERP 95.5% of peak 250°: 0.5 dB attenuation; relative ERP 89.1% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 1.5 dB attenuation; relative ERP 70.8% of peak 280°: 2 dB attenuation; relative ERP 63.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 4 dB attenuation; relative ERP 39.8% of peak 310°: 5 dB attenuation; relative ERP 31.6% of peak 320°: 6 dB attenuation; relative ERP 25.1% of peak 330°: 7 dB attenuation; relative ERP 20% of peak 340°: 7.5 dB attenuation; relative ERP 17.8% of peak 350°: 8 dB attenuation; relative ERP 15.8% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 170°, 180°, 190°, 200°, 210°, 220°, 230° at 0 dB attenuation.

Deepest restriction(s): 40° at 19 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 50 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 6 dB attenuation; relative ERP 25.1% of peak 20°: 6 dB attenuation; relative ERP 25.1% of peak 30°: 6 dB attenuation; relative ERP 25.1% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 6 dB attenuation; relative ERP 25.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 350° at 6 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 50 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 6 dB attenuation; relative ERP 25.1% of peak 20°: 6 dB attenuation; relative ERP 25.1% of peak 30°: 6 dB attenuation; relative ERP 25.1% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 6 dB attenuation; relative ERP 25.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 350° at 6 dB attenuation.

Parameters

Date 11/09/2018
Station West Somerset Radio
Area Minehead
Site Minehead North
Licence CR102172
mb21 Minehead North
Frequency 104.4
NGR SS96394728
RDS PS WEST_SOM
RDS PI CF9B
Switched PI
TP/TA N
TMC N
Lat 51.21529
Long -3.484815
Site Ht 169
In-Use Aerial Ht 15
In-UseERP/HP 1 W
In-Use ERP/VP 50.2 W
Max Dir
Licensed ERP/HP 50 W
Licensed ERP/VP 50 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
912141819141297.5654321.510.500000000.20.511.52345677.58

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
666600000000000000000000000000000006

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
666600000000000000000000000000000006