Warminster Town - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Warminster Town

Warminster · WCR · 105.5 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 25.3 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0.6 dB attenuation; relative ERP 87.1% of peak 40°: 1.5 dB attenuation; relative ERP 70.8% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 4 dB attenuation; relative ERP 39.8% of peak 70°: 6 dB attenuation; relative ERP 25.1% of peak 80°: 8 dB attenuation; relative ERP 15.8% of peak 90°: 12 dB attenuation; relative ERP 6.3% of peak 100°: 19 dB attenuation; relative ERP 1.3% of peak 110°: 30 dB attenuation; relative ERP 0.1% of peak 120°: 14 dB attenuation; relative ERP 4% of peak 130°: 9 dB attenuation; relative ERP 12.6% of peak 140°: 6 dB attenuation; relative ERP 25.1% of peak 150°: 4 dB attenuation; relative ERP 39.8% of peak 160°: 3 dB attenuation; relative ERP 50.1% of peak 170°: 1 dB attenuation; relative ERP 79.4% of peak 180°: 0.5 dB attenuation; relative ERP 89.1% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0.5 dB attenuation; relative ERP 89.1% of peak 220°: 1 dB attenuation; relative ERP 79.4% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 3.5 dB attenuation; relative ERP 44.7% of peak 250°: 5 dB attenuation; relative ERP 31.6% of peak 260°: 8 dB attenuation; relative ERP 15.8% of peak 270°: 12 dB attenuation; relative ERP 6.3% of peak 280°: 19 dB attenuation; relative ERP 1.3% of peak 290°: 22 dB attenuation; relative ERP 0.6% of peak 300°: 14 dB attenuation; relative ERP 4% of peak 310°: 9 dB attenuation; relative ERP 12.6% of peak 320°: 6 dB attenuation; relative ERP 25.1% of peak 330°: 4 dB attenuation; relative ERP 39.8% of peak 340°: 2 dB attenuation; relative ERP 63.1% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 190°, 200° at 0 dB attenuation.

Deepest restriction(s): 110° at 30 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 25.3 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 4 dB attenuation; relative ERP 39.8% of peak 10°: 4 dB attenuation; relative ERP 39.8% of peak 20°: 4 dB attenuation; relative ERP 39.8% of peak 30°: 4 dB attenuation; relative ERP 39.8% of peak 40°: 4 dB attenuation; relative ERP 39.8% of peak 50°: 4 dB attenuation; relative ERP 39.8% of peak 60°: 4 dB attenuation; relative ERP 39.8% of peak 70°: 3 dB attenuation; relative ERP 50.1% of peak 80°: 2.5 dB attenuation; relative ERP 56.2% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 0.5 dB attenuation; relative ERP 89.1% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0.5 dB attenuation; relative ERP 89.1% of peak 280°: 1 dB attenuation; relative ERP 79.4% of peak 290°: 1.5 dB attenuation; relative ERP 70.8% of peak 300°: 2 dB attenuation; relative ERP 63.1% of peak 310°: 3 dB attenuation; relative ERP 50.1% of peak 320°: 3.5 dB attenuation; relative ERP 44.7% of peak 330°: 4 dB attenuation; relative ERP 39.8% of peak 340°: 4 dB attenuation; relative ERP 39.8% of peak 350°: 4 dB attenuation; relative ERP 39.8% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 330°, 340°, 350° at 4 dB attenuation.

Parameters

Date 06/03/2012
Station WCR
Area Warminster
Site Warminster Town
Licence CR000229
mb21 Warminster Town
Frequency 105.5
NGR ST87374516
RDS PS _WCRFM__
RDS PI C688
Switched PI
TP/TA
TMC
Lat 51.205508
Long -2.182169
Site Ht 117
In-Use Aerial Ht 19
In-UseERP/HP 25.3 W
In-Use ERP/VP 25.3 W
Max Dir 180
Licensed ERP/HP 25 W
Licensed ERP/VP 25 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
0000.61.5246812193014964310.5000.5123.5581219221496421

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
444444432.5210.50000000000000000.511.5233.5444