Barnstaple - North Devon college - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Barnstaple - North Devon college

Barnstaple · The Voice · 106.1 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 50 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 3 dB attenuation; relative ERP 50.1% of peak 10°: 3 dB attenuation; relative ERP 50.1% of peak 20°: 3 dB attenuation; relative ERP 50.1% of peak 30°: 3 dB attenuation; relative ERP 50.1% of peak 40°: 3 dB attenuation; relative ERP 50.1% of peak 50°: 3 dB attenuation; relative ERP 50.1% of peak 60°: 3 dB attenuation; relative ERP 50.1% of peak 70°: 3 dB attenuation; relative ERP 50.1% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 3 dB attenuation; relative ERP 50.1% of peak 100°: 2.7 dB attenuation; relative ERP 53.7% of peak 110°: 2.5 dB attenuation; relative ERP 56.2% of peak 120°: 2.25 dB attenuation; relative ERP 59.6% of peak 130°: 2 dB attenuation; relative ERP 63.1% of peak 140°: 1.5 dB attenuation; relative ERP 70.8% of peak 150°: 1 dB attenuation; relative ERP 79.4% of peak 160°: 0.5 dB attenuation; relative ERP 89.1% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0.5 dB attenuation; relative ERP 89.1% of peak 280°: 1 dB attenuation; relative ERP 79.4% of peak 290°: 1.5 dB attenuation; relative ERP 70.8% of peak 300°: 2 dB attenuation; relative ERP 63.1% of peak 310°: 2.25 dB attenuation; relative ERP 59.6% of peak 320°: 2.5 dB attenuation; relative ERP 56.2% of peak 330°: 2.7 dB attenuation; relative ERP 53.7% of peak 340°: 3 dB attenuation; relative ERP 50.1% of peak 350°: 3 dB attenuation; relative ERP 50.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 340°, 350° at 3 dB attenuation.

Parameters

Date 20/12/2013
Station The Voice
Area Barnstaple
Site Barnstaple - North Devon college
Licence CR000238
mb21 Barnstaple (North Devon College)
Frequency 106.1
NGR SS55203241
RDS PS TheVoice
RDS PI CD9C
Switched PI
TP/TA
TMC
Lat 51.0727
Long -4.068214
Site Ht 49
In-Use Aerial Ht 16
In-UseERP/HP 0 W
In-Use ERP/VP 50 W
Max Dir 225
Licensed ERP/HP 50 W
Licensed ERP/VP 50 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
33333333332.72.52.2521.510.500000000000.511.522.252.52.733