Doncaster - Civic Centre - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Doncaster - Civic Centre

Doncaster · Sine FM · 102.6 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 1.7 dB attenuation; relative ERP 67.6% of peak 10°: 1.5 dB attenuation; relative ERP 70.8% of peak 20°: 1 dB attenuation; relative ERP 79.4% of peak 30°: 0.8 dB attenuation; relative ERP 83.2% of peak 40°: 0.7 dB attenuation; relative ERP 85.1% of peak 50°: 0.6 dB attenuation; relative ERP 87.1% of peak 60°: 0.5 dB attenuation; relative ERP 89.1% of peak 70°: 0.4 dB attenuation; relative ERP 91.2% of peak 80°: 0.4 dB attenuation; relative ERP 91.2% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 2.6 dB attenuation; relative ERP 55% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 3.2 dB attenuation; relative ERP 47.9% of peak 210°: 3.5 dB attenuation; relative ERP 44.7% of peak 220°: 3.7 dB attenuation; relative ERP 42.7% of peak 230°: 4 dB attenuation; relative ERP 39.8% of peak 240°: 4.2 dB attenuation; relative ERP 38% of peak 250°: 4.5 dB attenuation; relative ERP 35.5% of peak 260°: 5 dB attenuation; relative ERP 31.6% of peak 270°: 5 dB attenuation; relative ERP 31.6% of peak 280°: 5 dB attenuation; relative ERP 31.6% of peak 290°: 4 dB attenuation; relative ERP 39.8% of peak 300°: 3.7 dB attenuation; relative ERP 42.7% of peak 310°: 3.3 dB attenuation; relative ERP 46.8% of peak 320°: 3 dB attenuation; relative ERP 50.1% of peak 330°: 2.7 dB attenuation; relative ERP 53.7% of peak 340°: 2.5 dB attenuation; relative ERP 56.2% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 90°, 100°, 110°, 120°, 130°, 140°, 150° at 0 dB attenuation.

Deepest restriction(s): 260°, 270°, 280° at 5 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 6 dB attenuation; relative ERP 25.1% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 6 dB attenuation; relative ERP 25.1% of peak 310°: 6 dB attenuation; relative ERP 25.1% of peak 320°: 6 dB attenuation; relative ERP 25.1% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 6 dB attenuation; relative ERP 25.1% of peak 350°: 6 dB attenuation; relative ERP 25.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250° at 0 dB attenuation.

Deepest restriction(s): 0°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 6 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 6 dB attenuation; relative ERP 25.1% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 6 dB attenuation; relative ERP 25.1% of peak 310°: 6 dB attenuation; relative ERP 25.1% of peak 320°: 6 dB attenuation; relative ERP 25.1% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 6 dB attenuation; relative ERP 25.1% of peak 350°: 6 dB attenuation; relative ERP 25.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250° at 0 dB attenuation.

Deepest restriction(s): 0°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 6 dB attenuation.

Parameters

Date 01/10/2021
Station Sine FM
Area Doncaster
Site Doncaster - Civic Centre
Licence CR000150
Frequency 102.6
NGR SE57760299
RDS PS Sine_FM
RDS PI C896
Switched PI
TP/TA N
TMC N
Lat 53.520416
Long -1.130303
Site Ht 16
In-Use Aerial Ht 27
In-UseERP/HP 25 W
In-Use ERP/VP 100 W
Max Dir
Licensed ERP/HP 100 W
Licensed ERP/VP 100 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
1.71.510.80.70.60.50.40.40000000122.633.23.53.744.24.555543.73.332.72.52

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
600000000000000000000000006666666666

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
600000000000000000000000006666666666