Sheffield - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Sheffield

West Sheffield · Sheffield Live 93.2 FM · 93.2 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 6 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 5.5 dB attenuation; relative ERP 28.2% of peak 10°: 10.5 dB attenuation; relative ERP 8.9% of peak 20°: 13.5 dB attenuation; relative ERP 4.5% of peak 30°: 9.5 dB attenuation; relative ERP 11.2% of peak 40°: 8.5 dB attenuation; relative ERP 14.1% of peak 50°: 10.5 dB attenuation; relative ERP 8.9% of peak 60°: 13.5 dB attenuation; relative ERP 4.5% of peak 70°: 8.5 dB attenuation; relative ERP 14.1% of peak 80°: 4.5 dB attenuation; relative ERP 35.5% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 1.5 dB attenuation; relative ERP 70.8% of peak 110°: 1.5 dB attenuation; relative ERP 70.8% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 2.6 dB attenuation; relative ERP 55% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 2.9 dB attenuation; relative ERP 51.3% of peak 160°: 2.7 dB attenuation; relative ERP 53.7% of peak 170°: 4 dB attenuation; relative ERP 39.8% of peak 180°: 3.5 dB attenuation; relative ERP 44.7% of peak 190°: 2.7 dB attenuation; relative ERP 53.7% of peak 200°: 1.7 dB attenuation; relative ERP 67.6% of peak 210°: 1.5 dB attenuation; relative ERP 70.8% of peak 220°: 3.5 dB attenuation; relative ERP 44.7% of peak 230°: 8 dB attenuation; relative ERP 15.8% of peak 240°: 13.5 dB attenuation; relative ERP 4.5% of peak 250°: 7.5 dB attenuation; relative ERP 17.8% of peak 260°: 2.5 dB attenuation; relative ERP 56.2% of peak 270°: 0.5 dB attenuation; relative ERP 89.1% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0.5 dB attenuation; relative ERP 89.1% of peak 300°: 2 dB attenuation; relative ERP 63.1% of peak 310°: 3.7 dB attenuation; relative ERP 42.7% of peak 320°: 4.5 dB attenuation; relative ERP 35.5% of peak 330°: 3.5 dB attenuation; relative ERP 44.7% of peak 340°: 2.5 dB attenuation; relative ERP 56.2% of peak 350°: 3 dB attenuation; relative ERP 50.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 280° at 0 dB attenuation.

Deepest restriction(s): 20°, 60°, 240° at 13.5 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 1 dB attenuation; relative ERP 79.4% of peak 10°: 0.8 dB attenuation; relative ERP 83.2% of peak 20°: 0.9 dB attenuation; relative ERP 81.3% of peak 30°: 1 dB attenuation; relative ERP 79.4% of peak 40°: 1 dB attenuation; relative ERP 79.4% of peak 50°: 0.9 dB attenuation; relative ERP 81.3% of peak 60°: 0.6 dB attenuation; relative ERP 87.1% of peak 70°: 0.6 dB attenuation; relative ERP 87.1% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 3.5 dB attenuation; relative ERP 44.7% of peak 120°: 4 dB attenuation; relative ERP 39.8% of peak 130°: 4 dB attenuation; relative ERP 39.8% of peak 140°: 3.5 dB attenuation; relative ERP 44.7% of peak 150°: 3 dB attenuation; relative ERP 50.1% of peak 160°: 1.8 dB attenuation; relative ERP 66.1% of peak 170°: 0.5 dB attenuation; relative ERP 89.1% of peak 180°: 0.2 dB attenuation; relative ERP 95.5% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0.1 dB attenuation; relative ERP 97.7% of peak 210°: 0.8 dB attenuation; relative ERP 83.2% of peak 220°: 1.6 dB attenuation; relative ERP 69.2% of peak 230°: 3.6 dB attenuation; relative ERP 43.7% of peak 240°: 6.5 dB attenuation; relative ERP 22.4% of peak 250°: 11 dB attenuation; relative ERP 7.9% of peak 260°: 17 dB attenuation; relative ERP 2% of peak 270°: 15 dB attenuation; relative ERP 3.2% of peak 280°: 12.5 dB attenuation; relative ERP 5.6% of peak 290°: 11.5 dB attenuation; relative ERP 7.1% of peak 300°: 11 dB attenuation; relative ERP 7.9% of peak 310°: 9 dB attenuation; relative ERP 12.6% of peak 320°: 7 dB attenuation; relative ERP 20% of peak 330°: 5 dB attenuation; relative ERP 31.6% of peak 340°: 3 dB attenuation; relative ERP 50.1% of peak 350°: 1.5 dB attenuation; relative ERP 70.8% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 190° at 0 dB attenuation.

Deepest restriction(s): 260° at 17 dB attenuation.

Parameters

Date 18/09/2007
Station Sheffield Live 93.2 FM
Area West Sheffield
Site Sheffield
Licence CR000083
mb21 Sheffield MF (possible match)
Frequency 93.2
NGR SK32448706
RDS PS ShefLive
RDS PI CA81
Switched PI
TP/TA N
TMC
Lat 53.379402
Long -1.513808
Site Ht 247
In-Use Aerial Ht 45
In-UseERP/HP 6 W
In-Use ERP/VP 25 W
Max Dir 90
Licensed ERP/HP 25 W
Licensed ERP/VP 25 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
5.510.513.59.58.510.513.58.54.521.51.522.632.92.743.52.71.71.53.5813.57.52.50.500.523.74.53.52.53

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
10.80.9110.90.60.61233.5443.531.80.50.200.10.81.63.66.511171512.511.51197531.5