Butts Brow - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Butts Brow

Eastbourne · Seahaven FM · 95.6 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 8 dB attenuation; relative ERP 15.8% of peak 10°: 8 dB attenuation; relative ERP 15.8% of peak 20°: 9.5 dB attenuation; relative ERP 11.2% of peak 30°: 9 dB attenuation; relative ERP 12.6% of peak 40°: 8.5 dB attenuation; relative ERP 14.1% of peak 50°: 9 dB attenuation; relative ERP 12.6% of peak 60°: 6 dB attenuation; relative ERP 25.1% of peak 70°: 6 dB attenuation; relative ERP 25.1% of peak 80°: 5 dB attenuation; relative ERP 31.6% of peak 90°: 4 dB attenuation; relative ERP 39.8% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 2 dB attenuation; relative ERP 63.1% of peak 140°: 2 dB attenuation; relative ERP 63.1% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 2 dB attenuation; relative ERP 63.1% of peak 170°: 1.5 dB attenuation; relative ERP 70.8% of peak 180°: 0.5 dB attenuation; relative ERP 89.1% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0.5 dB attenuation; relative ERP 89.1% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 3.5 dB attenuation; relative ERP 44.7% of peak 230°: 4 dB attenuation; relative ERP 39.8% of peak 240°: 4 dB attenuation; relative ERP 39.8% of peak 250°: 4 dB attenuation; relative ERP 39.8% of peak 260°: 4 dB attenuation; relative ERP 39.8% of peak 270°: 5 dB attenuation; relative ERP 31.6% of peak 280°: 6.5 dB attenuation; relative ERP 22.4% of peak 290°: 7.5 dB attenuation; relative ERP 17.8% of peak 300°: 13 dB attenuation; relative ERP 5% of peak 310°: 15 dB attenuation; relative ERP 3.2% of peak 320°: 10 dB attenuation; relative ERP 10% of peak 330°: 9 dB attenuation; relative ERP 12.6% of peak 340°: 8 dB attenuation; relative ERP 15.8% of peak 350°: 8 dB attenuation; relative ERP 15.8% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 190° at 0 dB attenuation.

Deepest restriction(s): 310° at 15 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 6 dB attenuation; relative ERP 25.1% of peak 20°: 6 dB attenuation; relative ERP 25.1% of peak 30°: 6 dB attenuation; relative ERP 25.1% of peak 40°: 6 dB attenuation; relative ERP 25.1% of peak 50°: 3 dB attenuation; relative ERP 50.1% of peak 60°: 3 dB attenuation; relative ERP 50.1% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 3 dB attenuation; relative ERP 50.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40° at 6 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 25.1 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6 dB attenuation; relative ERP 25.1% of peak 10°: 6 dB attenuation; relative ERP 25.1% of peak 20°: 6 dB attenuation; relative ERP 25.1% of peak 30°: 6 dB attenuation; relative ERP 25.1% of peak 40°: 6 dB attenuation; relative ERP 25.1% of peak 50°: 3 dB attenuation; relative ERP 50.1% of peak 60°: 3 dB attenuation; relative ERP 50.1% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 3 dB attenuation; relative ERP 50.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40° at 6 dB attenuation.

Parameters

Date 03/11/2020
Station Seahaven FM
Area Eastbourne
Site Butts Brow
Licence CR000211
mb21 Butts Brow
Frequency 95.6
NGR TQ58000152
RDS PS Seahaven
RDS PI CF83
Switched PI
TP/TA Y
TMC
Lat 50.791719
Long 0.240348
Site Ht 184
In-Use Aerial Ht 12
In-UseERP/HP 0 W
In-Use ERP/VP 25 W
Max Dir
Licensed ERP/HP 25 W
Licensed ERP/VP 25.1 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
889.598.59665432222221.50.500.523.5444456.57.5131510988

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
666663300000000000000000000000000003

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
666663300000000000000000000000000003