Purin Hill - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Purin Hill

Glenrothes · Original 106 · 96.1 MHz

Historic names: Kingdom FM (licence AL100771)

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 250 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 5 dB attenuation; relative ERP 31.6% of peak 10°: 5 dB attenuation; relative ERP 31.6% of peak 20°: 1.5 dB attenuation; relative ERP 70.8% of peak 30°: 3 dB attenuation; relative ERP 50.1% of peak 40°: 3 dB attenuation; relative ERP 50.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 2 dB attenuation; relative ERP 63.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 4 dB attenuation; relative ERP 39.8% of peak 160°: 4 dB attenuation; relative ERP 39.8% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 2 dB attenuation; relative ERP 63.1% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 6 dB attenuation; relative ERP 25.1% of peak 220°: 10 dB attenuation; relative ERP 10% of peak 230°: 16 dB attenuation; relative ERP 2.5% of peak 240°: 16 dB attenuation; relative ERP 2.5% of peak 250°: 10 dB attenuation; relative ERP 10% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 10 dB attenuation; relative ERP 10% of peak 280°: 12 dB attenuation; relative ERP 6.3% of peak 290°: 11 dB attenuation; relative ERP 7.9% of peak 300°: 12 dB attenuation; relative ERP 6.3% of peak 310°: 18 dB attenuation; relative ERP 1.6% of peak 320°: 12 dB attenuation; relative ERP 6.3% of peak 330°: 8 dB attenuation; relative ERP 15.8% of peak 340°: 6 dB attenuation; relative ERP 25.1% of peak 350°: 6 dB attenuation; relative ERP 25.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 170°, 180° at 0 dB attenuation.

Deepest restriction(s): 310° at 18 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 250 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 3.5 dB attenuation; relative ERP 44.7% of peak 20°: 4 dB attenuation; relative ERP 39.8% of peak 30°: 6 dB attenuation; relative ERP 25.1% of peak 40°: 4 dB attenuation; relative ERP 39.8% of peak 50°: 5 dB attenuation; relative ERP 31.6% of peak 60°: 5 dB attenuation; relative ERP 31.6% of peak 70°: 5 dB attenuation; relative ERP 31.6% of peak 80°: 6 dB attenuation; relative ERP 25.1% of peak 90°: 6 dB attenuation; relative ERP 25.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 1 dB attenuation; relative ERP 79.4% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 2 dB attenuation; relative ERP 63.1% of peak 140°: 2 dB attenuation; relative ERP 63.1% of peak 150°: 3 dB attenuation; relative ERP 50.1% of peak 160°: 3 dB attenuation; relative ERP 50.1% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 2 dB attenuation; relative ERP 63.1% of peak 190°: 2 dB attenuation; relative ERP 63.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 7 dB attenuation; relative ERP 20% of peak 220°: 14 dB attenuation; relative ERP 4% of peak 230°: 12 dB attenuation; relative ERP 6.3% of peak 240°: 12 dB attenuation; relative ERP 6.3% of peak 250°: 10 dB attenuation; relative ERP 10% of peak 260°: 8 dB attenuation; relative ERP 15.8% of peak 270°: 10 dB attenuation; relative ERP 10% of peak 280°: 12 dB attenuation; relative ERP 6.3% of peak 290°: 10 dB attenuation; relative ERP 10% of peak 300°: 9 dB attenuation; relative ERP 12.6% of peak 310°: 10 dB attenuation; relative ERP 10% of peak 320°: 6 dB attenuation; relative ERP 25.1% of peak 330°: 4 dB attenuation; relative ERP 39.8% of peak 340°: 1 dB attenuation; relative ERP 79.4% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 170° at 0 dB attenuation.

Deepest restriction(s): 220° at 14 dB attenuation.

Parameters

Date 22/08/1998
Station Original 106
Area Glenrothes
Site Purin Hill
Licence AL100771
mb21 Purin Hill
MCA map Open Ofcom MCA map
Frequency 96.1
NGR NO25270593
RDS PS Original
RDS PI C9B7
Switched PI
TP/TA Y
TMC
Lat 56.240005
Long -3.207286
Site Ht 337
In-Use Aerial Ht 22
In-UseERP/HP 250 W
In-Use ERP/VP 250 W
Max Dir 170
Licensed ERP/HP 250 W
Licensed ERP/VP 250 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
551.53321111132234400226101616106101211121812866

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
03.5464555663122233022371412121081012109106412