Newton Wick - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Newton Wick

Wick · Moray Firth Radio FM · 96.7 MHz

Historic names: MFR (licence AL000057)

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 10 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 3 dB attenuation; relative ERP 50.1% of peak 10°: 2.5 dB attenuation; relative ERP 56.2% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 2 dB attenuation; relative ERP 63.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 2 dB attenuation; relative ERP 63.1% of peak 70°: 2 dB attenuation; relative ERP 63.1% of peak 80°: 2 dB attenuation; relative ERP 63.1% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 1.5 dB attenuation; relative ERP 70.8% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 0.5 dB attenuation; relative ERP 89.1% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0.5 dB attenuation; relative ERP 89.1% of peak 200°: 0.7 dB attenuation; relative ERP 85.1% of peak 210°: 1 dB attenuation; relative ERP 79.4% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 3 dB attenuation; relative ERP 50.1% of peak 240°: 4 dB attenuation; relative ERP 39.8% of peak 250°: 5 dB attenuation; relative ERP 31.6% of peak 260°: 5 dB attenuation; relative ERP 31.6% of peak 270°: 5 dB attenuation; relative ERP 31.6% of peak 280°: 5.5 dB attenuation; relative ERP 28.2% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 7 dB attenuation; relative ERP 20% of peak 310°: 6 dB attenuation; relative ERP 25.1% of peak 320°: 5 dB attenuation; relative ERP 31.6% of peak 330°: 4 dB attenuation; relative ERP 39.8% of peak 340°: 3 dB attenuation; relative ERP 50.1% of peak 350°: 3 dB attenuation; relative ERP 50.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 150°, 160°, 170°, 180° at 0 dB attenuation.

Deepest restriction(s): 300° at 7 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 10 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 2.5 dB attenuation; relative ERP 56.2% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 3.5 dB attenuation; relative ERP 44.7% of peak 140°: 4 dB attenuation; relative ERP 39.8% of peak 150°: 5.5 dB attenuation; relative ERP 28.2% of peak 160°: 6 dB attenuation; relative ERP 25.1% of peak 170°: 6 dB attenuation; relative ERP 25.1% of peak 180°: 6 dB attenuation; relative ERP 25.1% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 6 dB attenuation; relative ERP 25.1% of peak 210°: 6 dB attenuation; relative ERP 25.1% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 6 dB attenuation; relative ERP 25.1% of peak 240°: 6 dB attenuation; relative ERP 25.1% of peak 250°: 7 dB attenuation; relative ERP 20% of peak 260°: 7 dB attenuation; relative ERP 20% of peak 270°: 7 dB attenuation; relative ERP 20% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 5 dB attenuation; relative ERP 31.6% of peak 300°: 4 dB attenuation; relative ERP 39.8% of peak 310°: 3 dB attenuation; relative ERP 50.1% of peak 320°: 2 dB attenuation; relative ERP 63.1% of peak 330°: 1 dB attenuation; relative ERP 79.4% of peak 340°: 0.5 dB attenuation; relative ERP 89.1% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 350° at 0 dB attenuation.

Deepest restriction(s): 250°, 260°, 270° at 7 dB attenuation.

Parameters

Date 10/05/2017
Station Moray Firth Radio FM
Area Wick
Site Newton Wick
Licence AL000057
mb21 Newton Wick
MCA map Open Ofcom MCA map
Frequency 96.7
NGR ND34804976
RDS PS __MFR__
RDS PI CBB1
Switched PI
TP/TA
TMC
Lat 58.431278
Long -3.118202
Site Ht 46
In-Use Aerial Ht 10
In-UseERP/HP 10 W
In-Use ERP/VP 10 W
Max Dir 50
Licensed ERP/HP 25 W
Licensed ERP/VP 25 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
32.522222222221.510.500000.50.712345555.56765433

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000122.533.545.56666666667776543210.50