Tor Sliasg - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Tor Sliasg

Moray · KCR · 107.7 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 380 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 26 dB attenuation; relative ERP 0.3% of peak 10°: 12 dB attenuation; relative ERP 6.3% of peak 20°: 8 dB attenuation; relative ERP 15.8% of peak 30°: 6 dB attenuation; relative ERP 25.1% of peak 40°: 4 dB attenuation; relative ERP 39.8% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 1 dB attenuation; relative ERP 79.4% of peak 130°: 2 dB attenuation; relative ERP 63.1% of peak 140°: 4 dB attenuation; relative ERP 39.8% of peak 150°: 6 dB attenuation; relative ERP 25.1% of peak 160°: 8 dB attenuation; relative ERP 15.8% of peak 170°: 12 dB attenuation; relative ERP 6.3% of peak 180°: 26 dB attenuation; relative ERP 0.3% of peak 190°: 18 dB attenuation; relative ERP 1.6% of peak 200°: 12 dB attenuation; relative ERP 6.3% of peak 210°: 8 dB attenuation; relative ERP 15.8% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 4 dB attenuation; relative ERP 39.8% of peak 240°: 2 dB attenuation; relative ERP 63.1% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 1 dB attenuation; relative ERP 79.4% of peak 300°: 2 dB attenuation; relative ERP 63.1% of peak 310°: 4 dB attenuation; relative ERP 39.8% of peak 320°: 6 dB attenuation; relative ERP 25.1% of peak 330°: 8 dB attenuation; relative ERP 15.8% of peak 340°: 12 dB attenuation; relative ERP 6.3% of peak 350°: 18 dB attenuation; relative ERP 1.6% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 70°, 80°, 90°, 100°, 110°, 260°, 270°, 280° at 0 dB attenuation.

Deepest restriction(s): 0°, 180° at 26 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 470 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 2 dB attenuation; relative ERP 63.1% of peak 10°: 4 dB attenuation; relative ERP 39.8% of peak 20°: 5 dB attenuation; relative ERP 31.6% of peak 30°: 6 dB attenuation; relative ERP 25.1% of peak 40°: 8 dB attenuation; relative ERP 15.8% of peak 50°: 10 dB attenuation; relative ERP 10% of peak 60°: 14 dB attenuation; relative ERP 4% of peak 70°: 16 dB attenuation; relative ERP 2.5% of peak 80°: 18 dB attenuation; relative ERP 1.6% of peak 90°: 14 dB attenuation; relative ERP 4% of peak 100°: 10 dB attenuation; relative ERP 10% of peak 110°: 8 dB attenuation; relative ERP 15.8% of peak 120°: 6 dB attenuation; relative ERP 25.1% of peak 130°: 5 dB attenuation; relative ERP 31.6% of peak 140°: 4 dB attenuation; relative ERP 39.8% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 80° at 18 dB attenuation.

Parameters

Date 30/09/2014
Station KCR
Area Moray
Site Tor Sliasg
Licence CR000264
mb21 Tor Sliasg
Frequency 107.7
NGR NJ42395818
RDS PS K C R
RDS PI CB84
Switched PI
TP/TA N
TMC
Lat 57.609916
Long -2.965824
Site Ht 293
In-Use Aerial Ht 25
In-UseERP/HP 380 W
In-Use ERP/VP 470 W
Max Dir 270
Licensed ERP/HP 600 W
Licensed ERP/VP 600 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
26128642100000124681226181286421000124681218

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
245681014161814108654200000000000000000000