Belfast - Conway Mill - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Belfast - Conway Mill

Belfast · Juice FM Belfast · 103.8 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 25 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 4 dB attenuation; relative ERP 39.8% of peak 10°: 4 dB attenuation; relative ERP 39.8% of peak 20°: 3.6 dB attenuation; relative ERP 43.7% of peak 30°: 3.2 dB attenuation; relative ERP 47.9% of peak 40°: 2.8 dB attenuation; relative ERP 52.5% of peak 50°: 2.4 dB attenuation; relative ERP 57.5% of peak 60°: 1.8 dB attenuation; relative ERP 66.1% of peak 70°: 1.4 dB attenuation; relative ERP 72.4% of peak 80°: 0.8 dB attenuation; relative ERP 83.2% of peak 90°: 0.4 dB attenuation; relative ERP 91.2% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0.1 dB attenuation; relative ERP 97.7% of peak 230°: 0.3 dB attenuation; relative ERP 93.3% of peak 240°: 0.5 dB attenuation; relative ERP 89.1% of peak 250°: 0.8 dB attenuation; relative ERP 83.2% of peak 260°: 1.3 dB attenuation; relative ERP 74.1% of peak 270°: 1.7 dB attenuation; relative ERP 67.6% of peak 280°: 2.7 dB attenuation; relative ERP 53.7% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 3.7 dB attenuation; relative ERP 42.7% of peak 310°: 3.9 dB attenuation; relative ERP 40.7% of peak 320°: 4 dB attenuation; relative ERP 39.8% of peak 330°: 4 dB attenuation; relative ERP 39.8% of peak 340°: 4 dB attenuation; relative ERP 39.8% of peak 350°: 4 dB attenuation; relative ERP 39.8% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 320°, 330°, 340°, 350° at 4 dB attenuation.

Parameters

Date 30/07/2018
Station Juice FM Belfast
Area Belfast
Site Belfast - Conway Mill
Licence CR102273
Frequency 103.8
NGR IJ32487428
RDS PS Juice___
RDS PI C051
Switched PI
TP/TA N
TMC
Lat 54.599372
Long -5.950909
Site Ht 19
In-Use Aerial Ht 24
In-UseERP/HP 0 W
In-Use ERP/VP 25 W
Max Dir
Licensed ERP/HP 25 W
Licensed ERP/VP 25 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
443.63.22.82.41.81.40.80.40000000000000.10.30.50.81.31.72.733.73.94444