Ryde Pier - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Ryde Pier

Ryde · Isle of Wight Radio · 102 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 20 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 20 dB attenuation; relative ERP 1% of peak 10°: 20 dB attenuation; relative ERP 1% of peak 20°: 20 dB attenuation; relative ERP 1% of peak 30°: 20 dB attenuation; relative ERP 1% of peak 40°: 20 dB attenuation; relative ERP 1% of peak 50°: 15 dB attenuation; relative ERP 3.2% of peak 60°: 12 dB attenuation; relative ERP 6.3% of peak 70°: 10 dB attenuation; relative ERP 10% of peak 80°: 8 dB attenuation; relative ERP 15.8% of peak 90°: 6 dB attenuation; relative ERP 25.1% of peak 100°: 4 dB attenuation; relative ERP 39.8% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 1 dB attenuation; relative ERP 79.4% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 3 dB attenuation; relative ERP 50.1% of peak 230°: 4 dB attenuation; relative ERP 39.8% of peak 240°: 6 dB attenuation; relative ERP 25.1% of peak 250°: 8 dB attenuation; relative ERP 15.8% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 12 dB attenuation; relative ERP 6.3% of peak 280°: 15 dB attenuation; relative ERP 3.2% of peak 290°: 20 dB attenuation; relative ERP 1% of peak 300°: 20 dB attenuation; relative ERP 1% of peak 310°: 20 dB attenuation; relative ERP 1% of peak 320°: 20 dB attenuation; relative ERP 1% of peak 330°: 20 dB attenuation; relative ERP 1% of peak 340°: 20 dB attenuation; relative ERP 1% of peak 350°: 20 dB attenuation; relative ERP 1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 140°, 150°, 160°, 170°, 180°, 190° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 20 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 0 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 12 dB attenuation; relative ERP 6.3% of peak 10°: 12 dB attenuation; relative ERP 6.3% of peak 20°: 12 dB attenuation; relative ERP 6.3% of peak 30°: 12 dB attenuation; relative ERP 6.3% of peak 40°: 12 dB attenuation; relative ERP 6.3% of peak 50°: 12 dB attenuation; relative ERP 6.3% of peak 60°: 12 dB attenuation; relative ERP 6.3% of peak 70°: 10 dB attenuation; relative ERP 10% of peak 80°: 8 dB attenuation; relative ERP 15.8% of peak 90°: 6 dB attenuation; relative ERP 25.1% of peak 100°: 4 dB attenuation; relative ERP 39.8% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 1 dB attenuation; relative ERP 79.4% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 3 dB attenuation; relative ERP 50.1% of peak 230°: 4 dB attenuation; relative ERP 39.8% of peak 240°: 6 dB attenuation; relative ERP 25.1% of peak 250°: 8 dB attenuation; relative ERP 15.8% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 12 dB attenuation; relative ERP 6.3% of peak 280°: 12 dB attenuation; relative ERP 6.3% of peak 290°: 12 dB attenuation; relative ERP 6.3% of peak 300°: 12 dB attenuation; relative ERP 6.3% of peak 310°: 12 dB attenuation; relative ERP 6.3% of peak 320°: 12 dB attenuation; relative ERP 6.3% of peak 330°: 12 dB attenuation; relative ERP 6.3% of peak 340°: 12 dB attenuation; relative ERP 6.3% of peak 350°: 12 dB attenuation; relative ERP 6.3% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 140°, 150°, 160°, 170°, 180°, 190° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 12 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 20 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 12 dB attenuation; relative ERP 6.3% of peak 10°: 12 dB attenuation; relative ERP 6.3% of peak 20°: 12 dB attenuation; relative ERP 6.3% of peak 30°: 12 dB attenuation; relative ERP 6.3% of peak 40°: 12 dB attenuation; relative ERP 6.3% of peak 50°: 12 dB attenuation; relative ERP 6.3% of peak 60°: 12 dB attenuation; relative ERP 6.3% of peak 70°: 10 dB attenuation; relative ERP 10% of peak 80°: 8 dB attenuation; relative ERP 15.8% of peak 90°: 6 dB attenuation; relative ERP 25.1% of peak 100°: 4 dB attenuation; relative ERP 39.8% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 1 dB attenuation; relative ERP 79.4% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 3 dB attenuation; relative ERP 50.1% of peak 230°: 4 dB attenuation; relative ERP 39.8% of peak 240°: 6 dB attenuation; relative ERP 25.1% of peak 250°: 8 dB attenuation; relative ERP 15.8% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 12 dB attenuation; relative ERP 6.3% of peak 280°: 12 dB attenuation; relative ERP 6.3% of peak 290°: 12 dB attenuation; relative ERP 6.3% of peak 300°: 12 dB attenuation; relative ERP 6.3% of peak 310°: 12 dB attenuation; relative ERP 6.3% of peak 320°: 12 dB attenuation; relative ERP 6.3% of peak 330°: 12 dB attenuation; relative ERP 6.3% of peak 340°: 12 dB attenuation; relative ERP 6.3% of peak 350°: 12 dB attenuation; relative ERP 6.3% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 140°, 150°, 160°, 170°, 180°, 190° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 12 dB attenuation.

Parameters

Date 29/06/1998
Station Isle of Wight Radio
Area Ryde
Site Ryde Pier
Licence AL103882
mb21 Ryde Pier
MCA map Open Ofcom MCA map
Frequency 102
NGR SZ59359363
RDS PS IW_RADIO
RDS PI C8B7
Switched PI
TP/TA N
TMC
Lat 50.739256
Long -1.160281
Site Ht 0
In-Use Aerial Ht 13
In-UseERP/HP 0 W
In-Use ERP/VP 20 W
Max Dir 165
Licensed ERP/HP 0 W
Licensed ERP/VP 20 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
202020202015121086432100000012346810121520202020202020

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
121212121212121086432100000012346810121212121212121212

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
121212121212121086432100000012346810121212121212121212