Kilsyth - Corrie Farm - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Kilsyth - Corrie Farm

Cumbernauld · Home Radio · 100.8 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 7 dB attenuation; relative ERP 20% of peak 10°: 6.8 dB attenuation; relative ERP 20.9% of peak 20°: 6.5 dB attenuation; relative ERP 22.4% of peak 30°: 6 dB attenuation; relative ERP 25.1% of peak 40°: 5 dB attenuation; relative ERP 31.6% of peak 50°: 4 dB attenuation; relative ERP 39.8% of peak 60°: 3.7 dB attenuation; relative ERP 42.7% of peak 70°: 3 dB attenuation; relative ERP 50.1% of peak 80°: 2.3 dB attenuation; relative ERP 58.9% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 0.5 dB attenuation; relative ERP 89.1% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0.5 dB attenuation; relative ERP 89.1% of peak 130°: 1 dB attenuation; relative ERP 79.4% of peak 140°: 2.3 dB attenuation; relative ERP 58.9% of peak 150°: 3 dB attenuation; relative ERP 50.1% of peak 160°: 4 dB attenuation; relative ERP 39.8% of peak 170°: 5.3 dB attenuation; relative ERP 29.5% of peak 180°: 5.8 dB attenuation; relative ERP 26.3% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 6.5 dB attenuation; relative ERP 22.4% of peak 210°: 7 dB attenuation; relative ERP 20% of peak 220°: 7.5 dB attenuation; relative ERP 17.8% of peak 230°: 8 dB attenuation; relative ERP 15.8% of peak 240°: 9 dB attenuation; relative ERP 12.6% of peak 250°: 11 dB attenuation; relative ERP 7.9% of peak 260°: 12 dB attenuation; relative ERP 6.3% of peak 270°: 14 dB attenuation; relative ERP 4% of peak 280°: 14 dB attenuation; relative ERP 4% of peak 290°: 14 dB attenuation; relative ERP 4% of peak 300°: 12 dB attenuation; relative ERP 6.3% of peak 310°: 11 dB attenuation; relative ERP 7.9% of peak 320°: 9 dB attenuation; relative ERP 12.6% of peak 330°: 8 dB attenuation; relative ERP 15.8% of peak 340°: 7.8 dB attenuation; relative ERP 16.6% of peak 350°: 7.3 dB attenuation; relative ERP 18.6% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 110° at 0 dB attenuation.

Deepest restriction(s): 270°, 280°, 290° at 14 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 6 dB attenuation; relative ERP 25.1% of peak 160°: 6 dB attenuation; relative ERP 25.1% of peak 170°: 6 dB attenuation; relative ERP 25.1% of peak 180°: 6 dB attenuation; relative ERP 25.1% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 6 dB attenuation; relative ERP 25.1% of peak 210°: 6 dB attenuation; relative ERP 25.1% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 6 dB attenuation; relative ERP 25.1% of peak 240°: 6 dB attenuation; relative ERP 25.1% of peak 250°: 6 dB attenuation; relative ERP 25.1% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 6 dB attenuation; relative ERP 25.1% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290° at 6 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 6 dB attenuation; relative ERP 25.1% of peak 160°: 6 dB attenuation; relative ERP 25.1% of peak 170°: 6 dB attenuation; relative ERP 25.1% of peak 180°: 6 dB attenuation; relative ERP 25.1% of peak 190°: 6 dB attenuation; relative ERP 25.1% of peak 200°: 6 dB attenuation; relative ERP 25.1% of peak 210°: 6 dB attenuation; relative ERP 25.1% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 6 dB attenuation; relative ERP 25.1% of peak 240°: 6 dB attenuation; relative ERP 25.1% of peak 250°: 6 dB attenuation; relative ERP 25.1% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 6 dB attenuation; relative ERP 25.1% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290° at 6 dB attenuation.

Parameters

Date 02/12/2019
Station Home Radio
Area Cumbernauld
Site Kilsyth - Corrie Farm
Licence CR000020
Frequency 100.8
NGR NS69027911
RDS PS
RDS PI
Switched PI
TP/TA N
TMC
Lat 55.987025
Long -4.10111
Site Ht 257
In-Use Aerial Ht 9
In-UseERP/HP 0 W
In-Use ERP/VP 100 W
Max Dir
Licensed ERP/HP 100 W
Licensed ERP/VP 100 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
76.86.56543.732.310.500.512.3345.35.866.577.58911121414141211987.87.3

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000000666666666666666000000

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000000666666666666666000000