Windermere - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Windermere

Windermere · Heart (Morecambe Bay) · 102.3 MHz

Historic names: Heart North Lancashire & Cumbria, The Bay (licence AL000147)

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 8 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 1 dB attenuation; relative ERP 79.4% of peak 10°: 2 dB attenuation; relative ERP 63.1% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 2 dB attenuation; relative ERP 63.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 2 dB attenuation; relative ERP 63.1% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 1 dB attenuation; relative ERP 79.4% of peak 120°: 1 dB attenuation; relative ERP 79.4% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 1 dB attenuation; relative ERP 79.4% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 3 dB attenuation; relative ERP 50.1% of peak 190°: 4 dB attenuation; relative ERP 39.8% of peak 200°: 6 dB attenuation; relative ERP 25.1% of peak 210°: 8 dB attenuation; relative ERP 15.8% of peak 220°: 10 dB attenuation; relative ERP 10% of peak 230°: 11 dB attenuation; relative ERP 7.9% of peak 240°: 12 dB attenuation; relative ERP 6.3% of peak 250°: 11 dB attenuation; relative ERP 7.9% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 8 dB attenuation; relative ERP 15.8% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 4 dB attenuation; relative ERP 39.8% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 2 dB attenuation; relative ERP 63.1% of peak 320°: 1 dB attenuation; relative ERP 79.4% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 130°, 140°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 240° at 12 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 32 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 1 dB attenuation; relative ERP 79.4% of peak 10°: 2 dB attenuation; relative ERP 63.1% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 2 dB attenuation; relative ERP 63.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 2 dB attenuation; relative ERP 63.1% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 1 dB attenuation; relative ERP 79.4% of peak 120°: 1 dB attenuation; relative ERP 79.4% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 1 dB attenuation; relative ERP 79.4% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 3 dB attenuation; relative ERP 50.1% of peak 190°: 4 dB attenuation; relative ERP 39.8% of peak 200°: 6 dB attenuation; relative ERP 25.1% of peak 210°: 8 dB attenuation; relative ERP 15.8% of peak 220°: 10 dB attenuation; relative ERP 10% of peak 230°: 11 dB attenuation; relative ERP 7.9% of peak 240°: 12 dB attenuation; relative ERP 6.3% of peak 250°: 11 dB attenuation; relative ERP 7.9% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 8 dB attenuation; relative ERP 15.8% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 4 dB attenuation; relative ERP 39.8% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 2 dB attenuation; relative ERP 63.1% of peak 320°: 1 dB attenuation; relative ERP 79.4% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 130°, 140°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 240° at 12 dB attenuation.

Parameters

Date 28/07/1994
Station Heart (Morecambe Bay)
Area Windermere
Site Windermere
Licence AL000147
mb21 Windermere
MCA map Open Ofcom MCA map
Frequency 102.3
NGR SD38319808
RDS PS Heart
RDS PI C7A3
Switched PI
TP/TA Y
TMC
Lat 54.374471
Long -2.951155
Site Ht 219
In-Use Aerial Ht 22
In-UseERP/HP 8 W
In-Use ERP/VP 32 W
Max Dir 335
Licensed ERP/HP 32 W
Licensed ERP/VP 32 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
12222221112110011234681011121110864321000

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
12222221112110011234681011121110864321000