Morecambe Bay - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Morecambe Bay

Morecambe Bay · Heart (Morecambe Bay) · 96.9 MHz

Historic names: Heart North Lancashire & Cumbria, The Bay (licence AL000147)

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 1.6 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 14 dB attenuation; relative ERP 4% of peak 10°: 14 dB attenuation; relative ERP 4% of peak 20°: 14 dB attenuation; relative ERP 4% of peak 30°: 14 dB attenuation; relative ERP 4% of peak 40°: 14 dB attenuation; relative ERP 4% of peak 50°: 14 dB attenuation; relative ERP 4% of peak 60°: 8 dB attenuation; relative ERP 15.8% of peak 70°: 5 dB attenuation; relative ERP 31.6% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 3 dB attenuation; relative ERP 50.1% of peak 170°: 5 dB attenuation; relative ERP 31.6% of peak 180°: 8 dB attenuation; relative ERP 15.8% of peak 190°: 14 dB attenuation; relative ERP 4% of peak 200°: 14 dB attenuation; relative ERP 4% of peak 210°: 14 dB attenuation; relative ERP 4% of peak 220°: 14 dB attenuation; relative ERP 4% of peak 230°: 14 dB attenuation; relative ERP 4% of peak 240°: 14 dB attenuation; relative ERP 4% of peak 250°: 14 dB attenuation; relative ERP 4% of peak 260°: 14 dB attenuation; relative ERP 4% of peak 270°: 14 dB attenuation; relative ERP 4% of peak 280°: 14 dB attenuation; relative ERP 4% of peak 290°: 14 dB attenuation; relative ERP 4% of peak 300°: 14 dB attenuation; relative ERP 4% of peak 310°: 14 dB attenuation; relative ERP 4% of peak 320°: 14 dB attenuation; relative ERP 4% of peak 330°: 14 dB attenuation; relative ERP 4% of peak 340°: 14 dB attenuation; relative ERP 4% of peak 350°: 14 dB attenuation; relative ERP 4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 110°, 120°, 130° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 50°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 14 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 1.6 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 10 dB attenuation; relative ERP 10% of peak 10°: 7 dB attenuation; relative ERP 20% of peak 20°: 5 dB attenuation; relative ERP 31.6% of peak 30°: 3 dB attenuation; relative ERP 50.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 5 dB attenuation; relative ERP 31.6% of peak 230°: 7 dB attenuation; relative ERP 20% of peak 240°: 10 dB attenuation; relative ERP 10% of peak 250°: 12 dB attenuation; relative ERP 6.3% of peak 260°: 14 dB attenuation; relative ERP 4% of peak 270°: 14 dB attenuation; relative ERP 4% of peak 280°: 14 dB attenuation; relative ERP 4% of peak 290°: 14 dB attenuation; relative ERP 4% of peak 300°: 14 dB attenuation; relative ERP 4% of peak 310°: 14 dB attenuation; relative ERP 4% of peak 320°: 14 dB attenuation; relative ERP 4% of peak 330°: 14 dB attenuation; relative ERP 4% of peak 340°: 14 dB attenuation; relative ERP 4% of peak 350°: 12 dB attenuation; relative ERP 6.3% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170° at 0 dB attenuation.

Deepest restriction(s): 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 14 dB attenuation.

Parameters

Date 15/02/1993
Station Heart (Morecambe Bay)
Area Morecambe Bay
Site Morecambe Bay
Licence AL000147
mb21 Morecambe Bay
MCA map Open Ofcom MCA map
Frequency 96.9
NGR SD23967916
RDS PS Heart
RDS PI C7A3
Switched PI
TP/TA Y
TMC Y
Lat 54.202526
Long -3.167193
Site Ht 259
In-Use Aerial Ht 67
In-UseERP/HP 1.6 kW
In-Use ERP/VP 1.6 kW
Max Dir 120
Licensed ERP/HP 1.6 kW
Licensed ERP/VP 1.6 kW

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
14141414141485321000123581414141414141414141414141414141414

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
1075322110000000000112357101214141414141414141412