In-use horizontal pattern
ERP field: In-UseERP/HP = 50 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 6 dB attenuation; relative ERP 25.1% of peak
10°: 6.6 dB attenuation; relative ERP 21.9% of peak
20°: 7 dB attenuation; relative ERP 20% of peak
30°: 8 dB attenuation; relative ERP 15.8% of peak
40°: 9 dB attenuation; relative ERP 12.6% of peak
50°: 10 dB attenuation; relative ERP 10% of peak
60°: 12 dB attenuation; relative ERP 6.3% of peak
70°: 14 dB attenuation; relative ERP 4% of peak
80°: 15 dB attenuation; relative ERP 3.2% of peak
90°: 15 dB attenuation; relative ERP 3.2% of peak
100°: 14 dB attenuation; relative ERP 4% of peak
110°: 10 dB attenuation; relative ERP 10% of peak
120°: 9 dB attenuation; relative ERP 12.6% of peak
130°: 7 dB attenuation; relative ERP 20% of peak
140°: 5 dB attenuation; relative ERP 31.6% of peak
150°: 4.4 dB attenuation; relative ERP 36.3% of peak
160°: 3.6 dB attenuation; relative ERP 43.7% of peak
170°: 3 dB attenuation; relative ERP 50.1% of peak
180°: 2 dB attenuation; relative ERP 63.1% of peak
190°: 1.9 dB attenuation; relative ERP 64.6% of peak
200°: 1 dB attenuation; relative ERP 79.4% of peak
210°: 0.8 dB attenuation; relative ERP 83.2% of peak
220°: 0.4 dB attenuation; relative ERP 91.2% of peak
230°: 0 dB attenuation; relative ERP 100% of peak
240°: 0 dB attenuation; relative ERP 100% of peak
250°: 0 dB attenuation; relative ERP 100% of peak
260°: 0.2 dB attenuation; relative ERP 95.5% of peak
270°: 0.3 dB attenuation; relative ERP 93.3% of peak
280°: 0.8 dB attenuation; relative ERP 83.2% of peak
290°: 1.2 dB attenuation; relative ERP 75.9% of peak
300°: 1.7 dB attenuation; relative ERP 67.6% of peak
310°: 2 dB attenuation; relative ERP 63.1% of peak
320°: 3 dB attenuation; relative ERP 50.1% of peak
330°: 3.5 dB attenuation; relative ERP 44.7% of peak
340°: 4 dB attenuation; relative ERP 39.8% of peak
350°: 5 dB attenuation; relative ERP 31.6% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 230°, 240°, 250° at 0 dB attenuation.
Deepest restriction(s): 80°, 90° at 15 dB attenuation.
In-use vertical pattern
ERP field: In-Use ERP/VP = 50 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 20 dB attenuation; relative ERP 1% of peak
10°: 20 dB attenuation; relative ERP 1% of peak
20°: 20 dB attenuation; relative ERP 1% of peak
30°: 20 dB attenuation; relative ERP 1% of peak
40°: 20 dB attenuation; relative ERP 1% of peak
50°: 20 dB attenuation; relative ERP 1% of peak
60°: 20 dB attenuation; relative ERP 1% of peak
70°: 20 dB attenuation; relative ERP 1% of peak
80°: 20 dB attenuation; relative ERP 1% of peak
90°: 20 dB attenuation; relative ERP 1% of peak
100°: 20 dB attenuation; relative ERP 1% of peak
110°: 20 dB attenuation; relative ERP 1% of peak
120°: 20 dB attenuation; relative ERP 1% of peak
130°: 20 dB attenuation; relative ERP 1% of peak
140°: 20 dB attenuation; relative ERP 1% of peak
150°: 16 dB attenuation; relative ERP 2.5% of peak
160°: 18 dB attenuation; relative ERP 1.6% of peak
170°: 11 dB attenuation; relative ERP 7.9% of peak
180°: 6.5 dB attenuation; relative ERP 22.4% of peak
190°: 5 dB attenuation; relative ERP 31.6% of peak
200°: 3.5 dB attenuation; relative ERP 44.7% of peak
210°: 2.5 dB attenuation; relative ERP 56.2% of peak
220°: 1.5 dB attenuation; relative ERP 70.8% of peak
230°: 1 dB attenuation; relative ERP 79.4% of peak
240°: 0 dB attenuation; relative ERP 100% of peak
250°: 0 dB attenuation; relative ERP 100% of peak
260°: 0 dB attenuation; relative ERP 100% of peak
270°: 1 dB attenuation; relative ERP 79.4% of peak
280°: 2.5 dB attenuation; relative ERP 56.2% of peak
290°: 4 dB attenuation; relative ERP 39.8% of peak
300°: 5 dB attenuation; relative ERP 31.6% of peak
310°: 6 dB attenuation; relative ERP 25.1% of peak
320°: 8 dB attenuation; relative ERP 15.8% of peak
330°: 10 dB attenuation; relative ERP 10% of peak
340°: 12 dB attenuation; relative ERP 6.3% of peak
350°: 17 dB attenuation; relative ERP 2% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 240°, 250°, 260° at 0 dB attenuation.
Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140° at 20 dB attenuation.