In-use horizontal pattern
ERP field: In-UseERP/HP = 23 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 3.5 dB attenuation; relative ERP 44.7% of peak
10°: 3 dB attenuation; relative ERP 50.1% of peak
20°: 2.7 dB attenuation; relative ERP 53.7% of peak
30°: 2.5 dB attenuation; relative ERP 56.2% of peak
40°: 2 dB attenuation; relative ERP 63.1% of peak
50°: 1.7 dB attenuation; relative ERP 67.6% of peak
60°: 1.2 dB attenuation; relative ERP 75.9% of peak
70°: 1.09 dB attenuation; relative ERP 77.8% of peak
80°: 0.7 dB attenuation; relative ERP 85.1% of peak
90°: 0.5 dB attenuation; relative ERP 89.1% of peak
100°: 0 dB attenuation; relative ERP 100% of peak
110°: 0 dB attenuation; relative ERP 100% of peak
120°: 0 dB attenuation; relative ERP 100% of peak
130°: 0 dB attenuation; relative ERP 100% of peak
140°: 0 dB attenuation; relative ERP 100% of peak
150°: 0 dB attenuation; relative ERP 100% of peak
160°: 0 dB attenuation; relative ERP 100% of peak
170°: 0.4 dB attenuation; relative ERP 91.2% of peak
180°: 1 dB attenuation; relative ERP 79.4% of peak
190°: 1.4 dB attenuation; relative ERP 72.4% of peak
200°: 2 dB attenuation; relative ERP 63.1% of peak
210°: 2.4 dB attenuation; relative ERP 57.5% of peak
220°: 3 dB attenuation; relative ERP 50.1% of peak
230°: 3.5 dB attenuation; relative ERP 44.7% of peak
240°: 4 dB attenuation; relative ERP 39.8% of peak
250°: 4.3 dB attenuation; relative ERP 37.2% of peak
260°: 4.5 dB attenuation; relative ERP 35.5% of peak
270°: 4.7 dB attenuation; relative ERP 33.9% of peak
280°: 5 dB attenuation; relative ERP 31.6% of peak
290°: 6 dB attenuation; relative ERP 25.1% of peak
300°: 6.5 dB attenuation; relative ERP 22.4% of peak
310°: 6 dB attenuation; relative ERP 25.1% of peak
320°: 5 dB attenuation; relative ERP 31.6% of peak
330°: 4.5 dB attenuation; relative ERP 35.5% of peak
340°: 4 dB attenuation; relative ERP 39.8% of peak
350°: 3.8 dB attenuation; relative ERP 41.7% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 100°, 110°, 120°, 130°, 140°, 150°, 160° at 0 dB attenuation.
Deepest restriction(s): 300° at 6.5 dB attenuation.