In-use horizontal pattern
ERP field: In-UseERP/HP = 80 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 10 dB attenuation; relative ERP 10% of peak
10°: 14 dB attenuation; relative ERP 4% of peak
20°: 14 dB attenuation; relative ERP 4% of peak
30°: 10 dB attenuation; relative ERP 10% of peak
40°: 7 dB attenuation; relative ERP 20% of peak
50°: 5 dB attenuation; relative ERP 31.6% of peak
60°: 4 dB attenuation; relative ERP 39.8% of peak
70°: 3 dB attenuation; relative ERP 50.1% of peak
80°: 2 dB attenuation; relative ERP 63.1% of peak
90°: 1 dB attenuation; relative ERP 79.4% of peak
100°: 0.5 dB attenuation; relative ERP 89.1% of peak
110°: 0 dB attenuation; relative ERP 100% of peak
120°: 0 dB attenuation; relative ERP 100% of peak
130°: 0.5 dB attenuation; relative ERP 89.1% of peak
140°: 1 dB attenuation; relative ERP 79.4% of peak
150°: 2 dB attenuation; relative ERP 63.1% of peak
160°: 3 dB attenuation; relative ERP 50.1% of peak
170°: 5 dB attenuation; relative ERP 31.6% of peak
180°: 7 dB attenuation; relative ERP 20% of peak
190°: 12 dB attenuation; relative ERP 6.3% of peak
200°: 18 dB attenuation; relative ERP 1.6% of peak
210°: 12 dB attenuation; relative ERP 6.3% of peak
220°: 7 dB attenuation; relative ERP 20% of peak
230°: 5 dB attenuation; relative ERP 31.6% of peak
240°: 4 dB attenuation; relative ERP 39.8% of peak
250°: 3 dB attenuation; relative ERP 50.1% of peak
260°: 4 dB attenuation; relative ERP 39.8% of peak
270°: 4 dB attenuation; relative ERP 39.8% of peak
280°: 4 dB attenuation; relative ERP 39.8% of peak
290°: 4 dB attenuation; relative ERP 39.8% of peak
300°: 3 dB attenuation; relative ERP 50.1% of peak
310°: 2.5 dB attenuation; relative ERP 56.2% of peak
320°: 2.5 dB attenuation; relative ERP 56.2% of peak
330°: 3 dB attenuation; relative ERP 50.1% of peak
340°: 4 dB attenuation; relative ERP 39.8% of peak
350°: 7 dB attenuation; relative ERP 20% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 110°, 120° at 0 dB attenuation.
Deepest restriction(s): 200° at 18 dB attenuation.
In-use vertical pattern
ERP field: In-Use ERP/VP = 100 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 2 dB attenuation; relative ERP 63.1% of peak
10°: 0.5 dB attenuation; relative ERP 89.1% of peak
20°: 0 dB attenuation; relative ERP 100% of peak
30°: 0 dB attenuation; relative ERP 100% of peak
40°: 0 dB attenuation; relative ERP 100% of peak
50°: 0 dB attenuation; relative ERP 100% of peak
60°: 0.5 dB attenuation; relative ERP 89.1% of peak
70°: 0.5 dB attenuation; relative ERP 89.1% of peak
80°: 0.5 dB attenuation; relative ERP 89.1% of peak
90°: 0.5 dB attenuation; relative ERP 89.1% of peak
100°: 0.5 dB attenuation; relative ERP 89.1% of peak
110°: 1 dB attenuation; relative ERP 79.4% of peak
120°: 1 dB attenuation; relative ERP 79.4% of peak
130°: 1 dB attenuation; relative ERP 79.4% of peak
140°: 1 dB attenuation; relative ERP 79.4% of peak
150°: 1 dB attenuation; relative ERP 79.4% of peak
160°: 1 dB attenuation; relative ERP 79.4% of peak
170°: 1 dB attenuation; relative ERP 79.4% of peak
180°: 1 dB attenuation; relative ERP 79.4% of peak
190°: 1 dB attenuation; relative ERP 79.4% of peak
200°: 1 dB attenuation; relative ERP 79.4% of peak
210°: 1.5 dB attenuation; relative ERP 70.8% of peak
220°: 2 dB attenuation; relative ERP 63.1% of peak
230°: 3 dB attenuation; relative ERP 50.1% of peak
240°: 4 dB attenuation; relative ERP 39.8% of peak
250°: 5 dB attenuation; relative ERP 31.6% of peak
260°: 6 dB attenuation; relative ERP 25.1% of peak
270°: 7 dB attenuation; relative ERP 20% of peak
280°: 7.5 dB attenuation; relative ERP 17.8% of peak
290°: 7.5 dB attenuation; relative ERP 17.8% of peak
300°: 7.5 dB attenuation; relative ERP 17.8% of peak
310°: 7 dB attenuation; relative ERP 20% of peak
320°: 6 dB attenuation; relative ERP 25.1% of peak
330°: 5 dB attenuation; relative ERP 31.6% of peak
340°: 4 dB attenuation; relative ERP 39.8% of peak
350°: 3 dB attenuation; relative ERP 50.1% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 20°, 30°, 40°, 50° at 0 dB attenuation.
Deepest restriction(s): 280°, 290°, 300° at 7.5 dB attenuation.