Stanton Moor - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Stanton Moor

Matlock · Greatest Hits Radio · 102 MHz

Historic names: Peak FM, Peak 107, Peak 107 FM (licence AL100839)

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 50 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 1 dB attenuation; relative ERP 79.4% of peak 10°: 2 dB attenuation; relative ERP 63.1% of peak 20°: 3.5 dB attenuation; relative ERP 44.7% of peak 30°: 6 dB attenuation; relative ERP 25.1% of peak 40°: 8 dB attenuation; relative ERP 15.8% of peak 50°: 9 dB attenuation; relative ERP 12.6% of peak 60°: 8 dB attenuation; relative ERP 15.8% of peak 70°: 6 dB attenuation; relative ERP 25.1% of peak 80°: 3.5 dB attenuation; relative ERP 44.7% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0.5 dB attenuation; relative ERP 89.1% of peak 140°: 1.5 dB attenuation; relative ERP 70.8% of peak 150°: 2.5 dB attenuation; relative ERP 56.2% of peak 160°: 4.5 dB attenuation; relative ERP 35.5% of peak 170°: 6 dB attenuation; relative ERP 25.1% of peak 180°: 8.5 dB attenuation; relative ERP 14.1% of peak 190°: 11 dB attenuation; relative ERP 7.9% of peak 200°: 12 dB attenuation; relative ERP 6.3% of peak 210°: 12 dB attenuation; relative ERP 6.3% of peak 220°: 12 dB attenuation; relative ERP 6.3% of peak 230°: 12 dB attenuation; relative ERP 6.3% of peak 240°: 12 dB attenuation; relative ERP 6.3% of peak 250°: 12 dB attenuation; relative ERP 6.3% of peak 260°: 12 dB attenuation; relative ERP 6.3% of peak 270°: 11 dB attenuation; relative ERP 7.9% of peak 280°: 8.5 dB attenuation; relative ERP 14.1% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 4.5 dB attenuation; relative ERP 35.5% of peak 310°: 2.5 dB attenuation; relative ERP 56.2% of peak 320°: 1.5 dB attenuation; relative ERP 70.8% of peak 330°: 0.5 dB attenuation; relative ERP 89.1% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 110°, 120°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 200°, 210°, 220°, 230°, 240°, 250°, 260° at 12 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 50 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 1 dB attenuation; relative ERP 79.4% of peak 10°: 2 dB attenuation; relative ERP 63.1% of peak 20°: 3.5 dB attenuation; relative ERP 44.7% of peak 30°: 6 dB attenuation; relative ERP 25.1% of peak 40°: 8 dB attenuation; relative ERP 15.8% of peak 50°: 9 dB attenuation; relative ERP 12.6% of peak 60°: 8 dB attenuation; relative ERP 15.8% of peak 70°: 6 dB attenuation; relative ERP 25.1% of peak 80°: 3.5 dB attenuation; relative ERP 44.7% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0.5 dB attenuation; relative ERP 89.1% of peak 140°: 1.5 dB attenuation; relative ERP 70.8% of peak 150°: 2.5 dB attenuation; relative ERP 56.2% of peak 160°: 4.5 dB attenuation; relative ERP 35.5% of peak 170°: 6 dB attenuation; relative ERP 25.1% of peak 180°: 8.5 dB attenuation; relative ERP 14.1% of peak 190°: 11 dB attenuation; relative ERP 7.9% of peak 200°: 12 dB attenuation; relative ERP 6.3% of peak 210°: 12 dB attenuation; relative ERP 6.3% of peak 220°: 12 dB attenuation; relative ERP 6.3% of peak 230°: 12 dB attenuation; relative ERP 6.3% of peak 240°: 12 dB attenuation; relative ERP 6.3% of peak 250°: 12 dB attenuation; relative ERP 6.3% of peak 260°: 12 dB attenuation; relative ERP 6.3% of peak 270°: 11 dB attenuation; relative ERP 7.9% of peak 280°: 8.5 dB attenuation; relative ERP 14.1% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 4.5 dB attenuation; relative ERP 35.5% of peak 310°: 2.5 dB attenuation; relative ERP 56.2% of peak 320°: 1.5 dB attenuation; relative ERP 70.8% of peak 330°: 0.5 dB attenuation; relative ERP 89.1% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 110°, 120°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 200°, 210°, 220°, 230°, 240°, 250°, 260° at 12 dB attenuation.

Parameters

Date 22/09/1998
Station Greatest Hits Radio
Area Matlock
Site Stanton Moor
Licence AL100839
mb21 Stanton Moor
MCA map Open Ofcom MCA map
Frequency 102
NGR SK24586374
RDS PS GRT_HITS
RDS PI C494
Switched PI
TP/TA Y
TMC
Lat 53.170211
Long -1.633756
Site Ht 305
In-Use Aerial Ht 40
In-UseERP/HP 50 W
In-Use ERP/VP 50 W
Max Dir
Licensed ERP/HP 50 W
Licensed ERP/VP 50 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
123.5689863.521000.51.52.54.568.51112121212121212118.564.52.51.50.500

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
123.5689863.521000.51.52.54.568.51112121212121212118.564.52.51.50.500