Glossop - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Glossop

Buxton · Greatest Hits Radio · 106.4 MHz

Historic names: Imagine Radio, High Peak Radio, Ashbourne Radio (licence AL100969)

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 250 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 8 dB attenuation; relative ERP 15.8% of peak 10°: 7 dB attenuation; relative ERP 20% of peak 20°: 6 dB attenuation; relative ERP 25.1% of peak 30°: 5 dB attenuation; relative ERP 31.6% of peak 40°: 3 dB attenuation; relative ERP 50.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 2 dB attenuation; relative ERP 63.1% of peak 70°: 1.5 dB attenuation; relative ERP 70.8% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 0.5 dB attenuation; relative ERP 89.1% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0.5 dB attenuation; relative ERP 89.1% of peak 150°: 1 dB attenuation; relative ERP 79.4% of peak 160°: 1.5 dB attenuation; relative ERP 70.8% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 3 dB attenuation; relative ERP 50.1% of peak 190°: 5 dB attenuation; relative ERP 31.6% of peak 200°: 6 dB attenuation; relative ERP 25.1% of peak 210°: 7 dB attenuation; relative ERP 20% of peak 220°: 9 dB attenuation; relative ERP 12.6% of peak 230°: 9.5 dB attenuation; relative ERP 11.2% of peak 240°: 11 dB attenuation; relative ERP 7.9% of peak 250°: 12 dB attenuation; relative ERP 6.3% of peak 260°: 12.5 dB attenuation; relative ERP 5.6% of peak 270°: 13 dB attenuation; relative ERP 5% of peak 280°: 13 dB attenuation; relative ERP 5% of peak 290°: 12 dB attenuation; relative ERP 6.3% of peak 300°: 14 dB attenuation; relative ERP 4% of peak 310°: 14 dB attenuation; relative ERP 4% of peak 320°: 14 dB attenuation; relative ERP 4% of peak 330°: 13 dB attenuation; relative ERP 5% of peak 340°: 12 dB attenuation; relative ERP 6.3% of peak 350°: 10 dB attenuation; relative ERP 10% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 100°, 110°, 120°, 130° at 0 dB attenuation.

Deepest restriction(s): 300°, 310°, 320° at 14 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 250 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 9 dB attenuation; relative ERP 12.6% of peak 10°: 7 dB attenuation; relative ERP 20% of peak 20°: 5 dB attenuation; relative ERP 31.6% of peak 30°: 4 dB attenuation; relative ERP 39.8% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 2 dB attenuation; relative ERP 63.1% of peak 190°: 4 dB attenuation; relative ERP 39.8% of peak 200°: 5 dB attenuation; relative ERP 31.6% of peak 210°: 7 dB attenuation; relative ERP 20% of peak 220°: 9 dB attenuation; relative ERP 12.6% of peak 230°: 10 dB attenuation; relative ERP 10% of peak 240°: 10 dB attenuation; relative ERP 10% of peak 250°: 10 dB attenuation; relative ERP 10% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 10 dB attenuation; relative ERP 10% of peak 280°: 10 dB attenuation; relative ERP 10% of peak 290°: 10 dB attenuation; relative ERP 10% of peak 300°: 10 dB attenuation; relative ERP 10% of peak 310°: 10 dB attenuation; relative ERP 10% of peak 320°: 10 dB attenuation; relative ERP 10% of peak 330°: 10 dB attenuation; relative ERP 10% of peak 340°: 10 dB attenuation; relative ERP 10% of peak 350°: 10 dB attenuation; relative ERP 10% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150° at 0 dB attenuation.

Deepest restriction(s): 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 10 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 250 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 9 dB attenuation; relative ERP 12.6% of peak 10°: 7 dB attenuation; relative ERP 20% of peak 20°: 5 dB attenuation; relative ERP 31.6% of peak 30°: 4 dB attenuation; relative ERP 39.8% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 2 dB attenuation; relative ERP 63.1% of peak 190°: 4 dB attenuation; relative ERP 39.8% of peak 200°: 5 dB attenuation; relative ERP 31.6% of peak 210°: 7 dB attenuation; relative ERP 20% of peak 220°: 9 dB attenuation; relative ERP 12.6% of peak 230°: 10 dB attenuation; relative ERP 10% of peak 240°: 10 dB attenuation; relative ERP 10% of peak 250°: 10 dB attenuation; relative ERP 10% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 10 dB attenuation; relative ERP 10% of peak 280°: 10 dB attenuation; relative ERP 10% of peak 290°: 10 dB attenuation; relative ERP 10% of peak 300°: 10 dB attenuation; relative ERP 10% of peak 310°: 10 dB attenuation; relative ERP 10% of peak 320°: 10 dB attenuation; relative ERP 10% of peak 330°: 10 dB attenuation; relative ERP 10% of peak 340°: 10 dB attenuation; relative ERP 10% of peak 350°: 10 dB attenuation; relative ERP 10% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 70°, 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150° at 0 dB attenuation.

Deepest restriction(s): 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 10 dB attenuation.

Parameters

Date 29/03/2004
Station Greatest Hits Radio
Area Buxton
Site Glossop
Licence AL100969
mb21 Glossop
MCA map Open Ofcom MCA map
Frequency 106.4
NGR SK02729538
RDS PS Grt_Hits
RDS PI C999
Switched PI
TP/TA Y
TMC
Lat 53.455169
Long -1.960506
Site Ht 262
In-Use Aerial Ht 40
In-UseERP/HP 0 W
In-Use ERP/VP 250 W
Max Dir 115
Licensed ERP/HP 250 W
Licensed ERP/VP 250 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
87653221.510.500000.511.52356799.5111212.5131312141414131210

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
9754221000000000122457910101010101010101010101010

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
9754221000000000122457910101010101010101010101010