Burley WT - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Burley WT

Rutland · Greatest Hits Radio · 107.2 MHz

Historic names: Rutland Radio (licence AL100877)

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 63.5 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 6.5 dB attenuation; relative ERP 22.4% of peak 10°: 6 dB attenuation; relative ERP 25.1% of peak 20°: 5 dB attenuation; relative ERP 31.6% of peak 30°: 3 dB attenuation; relative ERP 50.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 1 dB attenuation; relative ERP 79.4% of peak 60°: 0.2 dB attenuation; relative ERP 95.5% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0.5 dB attenuation; relative ERP 89.1% of peak 110°: 1 dB attenuation; relative ERP 79.4% of peak 120°: 1.2 dB attenuation; relative ERP 75.9% of peak 130°: 1.7 dB attenuation; relative ERP 67.6% of peak 140°: 2 dB attenuation; relative ERP 63.1% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 1.6 dB attenuation; relative ERP 69.2% of peak 170°: 1.2 dB attenuation; relative ERP 75.9% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 0.4 dB attenuation; relative ERP 91.2% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0.2 dB attenuation; relative ERP 95.5% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 2 dB attenuation; relative ERP 63.1% of peak 260°: 3 dB attenuation; relative ERP 50.1% of peak 270°: 5 dB attenuation; relative ERP 31.6% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 8 dB attenuation; relative ERP 15.8% of peak 300°: 8 dB attenuation; relative ERP 15.8% of peak 310°: 8 dB attenuation; relative ERP 15.8% of peak 320°: 7.7 dB attenuation; relative ERP 17% of peak 330°: 7.5 dB attenuation; relative ERP 17.8% of peak 340°: 7.2 dB attenuation; relative ERP 19.1% of peak 350°: 7 dB attenuation; relative ERP 20% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 70°, 80°, 90°, 200°, 210°, 220° at 0 dB attenuation.

Deepest restriction(s): 290°, 300°, 310° at 8 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 5 dB attenuation; relative ERP 31.6% of peak 310°: 5 dB attenuation; relative ERP 31.6% of peak 320°: 5 dB attenuation; relative ERP 31.6% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 300°, 310°, 320° at 5 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 5 dB attenuation; relative ERP 31.6% of peak 310°: 5 dB attenuation; relative ERP 31.6% of peak 320°: 5 dB attenuation; relative ERP 31.6% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 300°, 310°, 320° at 5 dB attenuation.

Parameters

Date 11/07/2017
Station Greatest Hits Radio
Area Rutland
Site Burley WT
Licence AL100877
MCA map Open Ofcom MCA map
Frequency 107.2
NGR SK89211125
RDS PS GRT_HITS
RDS PI C55F
Switched PI
TP/TA
TMC
Lat 52.691598
Long -0.681528
Site Ht 146
In-Use Aerial Ht 27
In-UseERP/HP 0 W
In-Use ERP/VP 63.5 W
Max Dir 80
Licensed ERP/HP 100 W
Licensed ERP/VP 100 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
6.5653210.20000.511.21.7221.61.210.40000.2123568887.77.57.27

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000002200000000000000000555000

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000002200000000000000000555000