Beacon Hill - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Beacon Hill

Torbay · Greatest Hits Radio · 105.5 MHz

Historic names: The Breeze, Palm 105.5, Palm FM (licence AL102316)

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 800 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0.5 dB attenuation; relative ERP 89.1% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 2.75 dB attenuation; relative ERP 53.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 2.5 dB attenuation; relative ERP 56.2% of peak 70°: 2.25 dB attenuation; relative ERP 59.6% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0.5 dB attenuation; relative ERP 89.1% of peak 110°: 2.5 dB attenuation; relative ERP 56.2% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 2.5 dB attenuation; relative ERP 56.2% of peak 140°: 2.5 dB attenuation; relative ERP 56.2% of peak 150°: 3 dB attenuation; relative ERP 50.1% of peak 160°: 2.5 dB attenuation; relative ERP 56.2% of peak 170°: 1 dB attenuation; relative ERP 79.4% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0.5 dB attenuation; relative ERP 89.1% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 2.75 dB attenuation; relative ERP 53.1% of peak 230°: 2.75 dB attenuation; relative ERP 53.1% of peak 240°: 3 dB attenuation; relative ERP 50.1% of peak 250°: 2.75 dB attenuation; relative ERP 53.1% of peak 260°: 1.5 dB attenuation; relative ERP 70.8% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0.5 dB attenuation; relative ERP 89.1% of peak 290°: 2 dB attenuation; relative ERP 63.1% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 2.75 dB attenuation; relative ERP 53.1% of peak 320°: 2.75 dB attenuation; relative ERP 53.1% of peak 330°: 3 dB attenuation; relative ERP 50.1% of peak 340°: 2.75 dB attenuation; relative ERP 53.1% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 90°, 180°, 270° at 0 dB attenuation.

Deepest restriction(s): 150°, 210°, 240°, 300°, 330° at 3 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 800 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 1 dB attenuation; relative ERP 79.4% of peak 10°: 1.25 dB attenuation; relative ERP 75% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 2 dB attenuation; relative ERP 63.1% of peak 40°: 0.5 dB attenuation; relative ERP 89.1% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 1.5 dB attenuation; relative ERP 70.8% of peak 70°: 3 dB attenuation; relative ERP 50.1% of peak 80°: 2.75 dB attenuation; relative ERP 53.1% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 1.25 dB attenuation; relative ERP 75% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 1.5 dB attenuation; relative ERP 70.8% of peak 130°: 0.25 dB attenuation; relative ERP 94.4% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 1.25 dB attenuation; relative ERP 75% of peak 160°: 3 dB attenuation; relative ERP 50.1% of peak 170°: 2.5 dB attenuation; relative ERP 56.2% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 1.75 dB attenuation; relative ERP 66.8% of peak 220°: 0.25 dB attenuation; relative ERP 94.4% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 1.25 dB attenuation; relative ERP 75% of peak 250°: 3 dB attenuation; relative ERP 50.1% of peak 260°: 2.5 dB attenuation; relative ERP 56.2% of peak 270°: 1 dB attenuation; relative ERP 79.4% of peak 280°: 1.25 dB attenuation; relative ERP 75% of peak 290°: 2 dB attenuation; relative ERP 63.1% of peak 300°: 1.75 dB attenuation; relative ERP 66.8% of peak 310°: 0.25 dB attenuation; relative ERP 94.4% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 1.25 dB attenuation; relative ERP 75% of peak 340°: 3 dB attenuation; relative ERP 50.1% of peak 350°: 2.5 dB attenuation; relative ERP 56.2% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 50°, 140°, 230°, 320° at 0 dB attenuation.

Deepest restriction(s): 70°, 160°, 250°, 340° at 3 dB attenuation.

Parameters

Date 11/06/2007
Station Greatest Hits Radio
Area Torbay
Site Beacon Hill
Licence AL102316
mb21 Beacon Hill
MCA map Open Ofcom MCA map
Frequency 105.5
NGR SX85726197
RDS PS GRT_HITS
RDS PI C3BB
Switched PI C7BB
TP/TA Y
TMC
Lat 50.44641
Long -3.610896
Site Ht 188
In-Use Aerial Ht 78
In-UseERP/HP 800 W
In-Use ERP/VP 800 W
Max Dir 40
Licensed ERP/HP 800 W
Licensed ERP/VP 800 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
00.522.75222.52.25100.52.522.52.532.5100.5232.752.7532.751.500.5232.752.7532.751

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
11.25220.501.532.7511.2521.50.2501.2532.51121.750.2501.2532.511.2521.750.2501.2532.5