Grantham - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Grantham

Grantham · Greatest Hits Lincolnshire · 96.7 MHz

Historic names: Lincs FM (licence AL000132)

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 35 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 1 dB attenuation; relative ERP 79.4% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 2 dB attenuation; relative ERP 63.1% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 5 dB attenuation; relative ERP 31.6% of peak 100°: 6 dB attenuation; relative ERP 25.1% of peak 110°: 9 dB attenuation; relative ERP 12.6% of peak 120°: 10 dB attenuation; relative ERP 10% of peak 130°: 11 dB attenuation; relative ERP 7.9% of peak 140°: 12 dB attenuation; relative ERP 6.3% of peak 150°: 13 dB attenuation; relative ERP 5% of peak 160°: 14 dB attenuation; relative ERP 4% of peak 170°: 15 dB attenuation; relative ERP 3.2% of peak 180°: 15 dB attenuation; relative ERP 3.2% of peak 190°: 15 dB attenuation; relative ERP 3.2% of peak 200°: 15 dB attenuation; relative ERP 3.2% of peak 210°: 15 dB attenuation; relative ERP 3.2% of peak 220°: 15 dB attenuation; relative ERP 3.2% of peak 230°: 15 dB attenuation; relative ERP 3.2% of peak 240°: 14 dB attenuation; relative ERP 4% of peak 250°: 13 dB attenuation; relative ERP 5% of peak 260°: 12 dB attenuation; relative ERP 6.3% of peak 270°: 11 dB attenuation; relative ERP 7.9% of peak 280°: 10 dB attenuation; relative ERP 10% of peak 290°: 9 dB attenuation; relative ERP 12.6% of peak 300°: 6 dB attenuation; relative ERP 25.1% of peak 310°: 5 dB attenuation; relative ERP 31.6% of peak 320°: 3 dB attenuation; relative ERP 50.1% of peak 330°: 2 dB attenuation; relative ERP 63.1% of peak 340°: 1 dB attenuation; relative ERP 79.4% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40° at 0 dB attenuation.

Deepest restriction(s): 170°, 180°, 190°, 200°, 210°, 220°, 230° at 15 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 50 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 3 dB attenuation; relative ERP 50.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 6 dB attenuation; relative ERP 25.1% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 6 dB attenuation; relative ERP 25.1% of peak 240°: 6 dB attenuation; relative ERP 25.1% of peak 250°: 6 dB attenuation; relative ERP 25.1% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 6 dB attenuation; relative ERP 25.1% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 6 dB attenuation; relative ERP 25.1% of peak 310°: 6 dB attenuation; relative ERP 25.1% of peak 320°: 6 dB attenuation; relative ERP 25.1% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330° at 6 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 50 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 3 dB attenuation; relative ERP 50.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 3 dB attenuation; relative ERP 50.1% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 6 dB attenuation; relative ERP 25.1% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 6 dB attenuation; relative ERP 25.1% of peak 240°: 6 dB attenuation; relative ERP 25.1% of peak 250°: 6 dB attenuation; relative ERP 25.1% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 6 dB attenuation; relative ERP 25.1% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 6 dB attenuation; relative ERP 25.1% of peak 310°: 6 dB attenuation; relative ERP 25.1% of peak 320°: 6 dB attenuation; relative ERP 25.1% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330° at 6 dB attenuation.

Parameters

Date 03/04/1995
Station Greatest Hits Lincolnshire
Area Grantham
Site Grantham
Licence AL000132
mb21 Grantham
MCA map Open Ofcom MCA map
Frequency 96.7
NGR SK90523362
RDS PS HITS_Lin
RDS PI C9B2
Switched PI
TP/TA Y
TMC
Lat 52.89242
Long -0.65597
Site Ht 115
In-Use Aerial Ht 17
In-UseERP/HP 0 W
In-Use ERP/VP 35 W
Max Dir 17
Licensed ERP/HP 50 W
Licensed ERP/VP 50 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
00000112356910111213141515151515151514131211109653211

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000003333000000000666666666666600

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000003333000000000666666666666600