In-use horizontal pattern
ERP field: In-UseERP/HP = 3.2 kW
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 2.4 dB attenuation; relative ERP 57.5% of peak
10°: 1.6 dB attenuation; relative ERP 69.2% of peak
20°: 1.5 dB attenuation; relative ERP 70.8% of peak
30°: 2 dB attenuation; relative ERP 63.1% of peak
40°: 2 dB attenuation; relative ERP 63.1% of peak
50°: 0.4 dB attenuation; relative ERP 91.2% of peak
60°: 0 dB attenuation; relative ERP 100% of peak
70°: 0.2 dB attenuation; relative ERP 95.5% of peak
80°: 1.5 dB attenuation; relative ERP 70.8% of peak
90°: 2.4 dB attenuation; relative ERP 57.5% of peak
100°: 1.6 dB attenuation; relative ERP 69.2% of peak
110°: 1.5 dB attenuation; relative ERP 70.8% of peak
120°: 2 dB attenuation; relative ERP 63.1% of peak
130°: 2 dB attenuation; relative ERP 63.1% of peak
140°: 0.4 dB attenuation; relative ERP 91.2% of peak
150°: 0 dB attenuation; relative ERP 100% of peak
160°: 0.2 dB attenuation; relative ERP 95.5% of peak
170°: 1.6 dB attenuation; relative ERP 69.2% of peak
180°: 2.4 dB attenuation; relative ERP 57.5% of peak
190°: 1.5 dB attenuation; relative ERP 70.8% of peak
200°: 1.5 dB attenuation; relative ERP 70.8% of peak
210°: 2 dB attenuation; relative ERP 63.1% of peak
220°: 2 dB attenuation; relative ERP 63.1% of peak
230°: 0.4 dB attenuation; relative ERP 91.2% of peak
240°: 0 dB attenuation; relative ERP 100% of peak
250°: 0.4 dB attenuation; relative ERP 91.2% of peak
260°: 1.6 dB attenuation; relative ERP 69.2% of peak
270°: 2.4 dB attenuation; relative ERP 57.5% of peak
280°: 1.5 dB attenuation; relative ERP 70.8% of peak
290°: 1.5 dB attenuation; relative ERP 70.8% of peak
300°: 2 dB attenuation; relative ERP 63.1% of peak
310°: 2 dB attenuation; relative ERP 63.1% of peak
320°: 0.4 dB attenuation; relative ERP 91.2% of peak
330°: 0 dB attenuation; relative ERP 100% of peak
340°: 0.2 dB attenuation; relative ERP 95.5% of peak
350°: 1.6 dB attenuation; relative ERP 69.2% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 60°, 150°, 240°, 330° at 0 dB attenuation.
Deepest restriction(s): 0°, 90°, 180°, 270° at 2.4 dB attenuation.
In-use vertical pattern
ERP field: In-Use ERP/VP = 3.2 kW
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 4 dB attenuation; relative ERP 39.8% of peak
10°: 1.6 dB attenuation; relative ERP 69.2% of peak
20°: 1 dB attenuation; relative ERP 79.4% of peak
30°: 3 dB attenuation; relative ERP 50.1% of peak
40°: 5 dB attenuation; relative ERP 31.6% of peak
50°: 2.5 dB attenuation; relative ERP 56.2% of peak
60°: 0 dB attenuation; relative ERP 100% of peak
70°: 0.5 dB attenuation; relative ERP 89.1% of peak
80°: 2.8 dB attenuation; relative ERP 52.5% of peak
90°: 5 dB attenuation; relative ERP 31.6% of peak
100°: 1.6 dB attenuation; relative ERP 69.2% of peak
110°: 1 dB attenuation; relative ERP 79.4% of peak
120°: 3 dB attenuation; relative ERP 50.1% of peak
130°: 5 dB attenuation; relative ERP 31.6% of peak
140°: 2.4 dB attenuation; relative ERP 57.5% of peak
150°: 0 dB attenuation; relative ERP 100% of peak
160°: 0.6 dB attenuation; relative ERP 87.1% of peak
170°: 3 dB attenuation; relative ERP 50.1% of peak
180°: 3.5 dB attenuation; relative ERP 44.7% of peak
190°: 1.5 dB attenuation; relative ERP 70.8% of peak
200°: 1.2 dB attenuation; relative ERP 75.9% of peak
210°: 3.2 dB attenuation; relative ERP 47.9% of peak
220°: 5 dB attenuation; relative ERP 31.6% of peak
230°: 2 dB attenuation; relative ERP 63.1% of peak
240°: 0 dB attenuation; relative ERP 100% of peak
250°: 0.6 dB attenuation; relative ERP 87.1% of peak
260°: 3 dB attenuation; relative ERP 50.1% of peak
270°: 3.5 dB attenuation; relative ERP 44.7% of peak
280°: 1.5 dB attenuation; relative ERP 70.8% of peak
290°: 1.4 dB attenuation; relative ERP 72.4% of peak
300°: 3.2 dB attenuation; relative ERP 47.9% of peak
310°: 5 dB attenuation; relative ERP 31.6% of peak
320°: 2.2 dB attenuation; relative ERP 60.3% of peak
330°: 0 dB attenuation; relative ERP 100% of peak
340°: 0.8 dB attenuation; relative ERP 83.2% of peak
350°: 3 dB attenuation; relative ERP 50.1% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 60°, 150°, 240°, 330° at 0 dB attenuation.
Deepest restriction(s): 40°, 90°, 130°, 220°, 310° at 5 dB attenuation.