Portland - Heights Hotel - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Portland - Heights Hotel

Weymouth · AIR · 107.2 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 3 dB attenuation; relative ERP 50.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 4 dB attenuation; relative ERP 39.8% of peak 160°: 4 dB attenuation; relative ERP 39.8% of peak 170°: 4 dB attenuation; relative ERP 39.8% of peak 180°: 4 dB attenuation; relative ERP 39.8% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 150°, 160°, 170°, 180° at 4 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 3 dB attenuation; relative ERP 50.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 4 dB attenuation; relative ERP 39.8% of peak 160°: 4 dB attenuation; relative ERP 39.8% of peak 170°: 4 dB attenuation; relative ERP 39.8% of peak 180°: 4 dB attenuation; relative ERP 39.8% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 150°, 160°, 170°, 180° at 4 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 1 dB attenuation; relative ERP 79.4% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 2 dB attenuation; relative ERP 63.1% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 3 dB attenuation; relative ERP 50.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 4 dB attenuation; relative ERP 39.8% of peak 160°: 4 dB attenuation; relative ERP 39.8% of peak 170°: 4 dB attenuation; relative ERP 39.8% of peak 180°: 4 dB attenuation; relative ERP 39.8% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 150°, 160°, 170°, 180° at 4 dB attenuation.

Parameters

Date 26/05/2025
Station AIR
Area Weymouth
Site Portland - Heights Hotel
Licence CR000243
Frequency 107.2
NGR SY68867297
RDS PS AIR____
RDS PI C588
Switched PI
TP/TA N
TMC N
Lat 50.555651
Long -2.440943
Site Ht 119
In-Use Aerial Ht 8
In-UseERP/HP 0 W
In-Use ERP/VP 100 W
Max Dir
Licensed ERP/HP 100 W
Licensed ERP/VP 100 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000011122333444433322111000000000

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000011122333444433322111000000000

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000011122333444433322111000000000