Stoke On Trent · Cross Rhythms City Radio · 101.8 MHz

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0.5 dB attenuation; relative ERP 89.1% of peak 30°: 1 dB attenuation; relative ERP 79.4% of peak 40°: 1.5 dB attenuation; relative ERP 70.8% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 2.6 dB attenuation; relative ERP 55% of peak 70°: 2.7 dB attenuation; relative ERP 53.7% of peak 80°: 3 dB attenuation; relative ERP 50.1% of peak 90°: 3.5 dB attenuation; relative ERP 44.7% of peak 100°: 4 dB attenuation; relative ERP 39.8% of peak 110°: 4.2 dB attenuation; relative ERP 38% of peak 120°: 4.5 dB attenuation; relative ERP 35.5% of peak 130°: 5 dB attenuation; relative ERP 31.6% of peak 140°: 4.5 dB attenuation; relative ERP 35.5% of peak 150°: 4.2 dB attenuation; relative ERP 38% of peak 160°: 4 dB attenuation; relative ERP 39.8% of peak 170°: 3.5 dB attenuation; relative ERP 44.7% of peak 180°: 3 dB attenuation; relative ERP 50.1% of peak 190°: 2.8 dB attenuation; relative ERP 52.5% of peak 200°: 2.6 dB attenuation; relative ERP 55% of peak 210°: 2.5 dB attenuation; relative ERP 56.2% of peak 220°: 2.4 dB attenuation; relative ERP 57.5% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1.5 dB attenuation; relative ERP 70.8% of peak 250°: 1.3 dB attenuation; relative ERP 74.1% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 0.5 dB attenuation; relative ERP 89.1% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 130° at 5 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 3 dB attenuation; relative ERP 50.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 3 dB attenuation; relative ERP 50.1% of peak 160°: 3 dB attenuation; relative ERP 50.1% of peak 170°: 3 dB attenuation; relative ERP 50.1% of peak 180°: 3 dB attenuation; relative ERP 50.1% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190° at 3 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 100 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 3 dB attenuation; relative ERP 50.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 3 dB attenuation; relative ERP 50.1% of peak 160°: 3 dB attenuation; relative ERP 50.1% of peak 170°: 3 dB attenuation; relative ERP 50.1% of peak 180°: 3 dB attenuation; relative ERP 50.1% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 100°, 110°, 200°, 210°, 220°, 230°, 240°, 250°, 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 120°, 130°, 140°, 150°, 160°, 170°, 180°, 190° at 3 dB attenuation.

Parameters

Date 12/01/2021
Station Cross Rhythms City Radio
Area Stoke On Trent
Site Stoke-on-Trent
Licence CR000003
Frequency 101.8
NGR SJ91794962
RDS PS CR_CITY
RDS PI C491
Switched PI
TP/TA N
TMC N
Lat 53.043784
Long -2.123907
Site Ht 213
In-Use Aerial Ht 30
In-UseERP/HP 25 W
In-Use ERP/VP 100 W
Max Dir
Licensed ERP/HP 100 W
Licensed ERP/VP 100 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000.511.522.62.733.544.24.554.54.243.532.82.62.52.421.51.310.500000000

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000333333330000000000000000

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
000000000000333333330000000000000000