In-use horizontal pattern

ERP field: In-UseERP/HP = 250 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 3 dB attenuation; relative ERP 50.1% of peak 10°: 5 dB attenuation; relative ERP 31.6% of peak 20°: 4 dB attenuation; relative ERP 39.8% of peak 30°: 4 dB attenuation; relative ERP 39.8% of peak 40°: 4 dB attenuation; relative ERP 39.8% of peak 50°: 3 dB attenuation; relative ERP 50.1% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 4 dB attenuation; relative ERP 39.8% of peak 110°: 4 dB attenuation; relative ERP 39.8% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 3 dB attenuation; relative ERP 50.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 1 dB attenuation; relative ERP 79.4% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 2 dB attenuation; relative ERP 63.1% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 3 dB attenuation; relative ERP 50.1% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 2 dB attenuation; relative ERP 63.1% of peak 280°: 3 dB attenuation; relative ERP 50.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 3 dB attenuation; relative ERP 50.1% of peak 320°: 3 dB attenuation; relative ERP 50.1% of peak 330°: 1 dB attenuation; relative ERP 79.4% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 70°, 80°, 160°, 170°, 250°, 340° at 0 dB attenuation.

Deepest restriction(s): 10° at 5 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 250 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 3 dB attenuation; relative ERP 50.1% of peak 10°: 5 dB attenuation; relative ERP 31.6% of peak 20°: 4 dB attenuation; relative ERP 39.8% of peak 30°: 4 dB attenuation; relative ERP 39.8% of peak 40°: 4 dB attenuation; relative ERP 39.8% of peak 50°: 3 dB attenuation; relative ERP 50.1% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 4 dB attenuation; relative ERP 39.8% of peak 110°: 4 dB attenuation; relative ERP 39.8% of peak 120°: 3 dB attenuation; relative ERP 50.1% of peak 130°: 3 dB attenuation; relative ERP 50.1% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 1 dB attenuation; relative ERP 79.4% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 2 dB attenuation; relative ERP 63.1% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 3 dB attenuation; relative ERP 50.1% of peak 230°: 2 dB attenuation; relative ERP 63.1% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 0 dB attenuation; relative ERP 100% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 2 dB attenuation; relative ERP 63.1% of peak 280°: 3 dB attenuation; relative ERP 50.1% of peak 290°: 3 dB attenuation; relative ERP 50.1% of peak 300°: 3 dB attenuation; relative ERP 50.1% of peak 310°: 3 dB attenuation; relative ERP 50.1% of peak 320°: 3 dB attenuation; relative ERP 50.1% of peak 330°: 1 dB attenuation; relative ERP 79.4% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 1 dB attenuation; relative ERP 79.4% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 70°, 80°, 160°, 170°, 250°, 340° at 0 dB attenuation.

Deepest restriction(s): 10° at 5 dB attenuation.

Parameters

Date 14/06/1993
Station Classic FM
Area South Yorkshire
Site Sheffield
Licence AN000001
mb21 Sheffield MF (possible match)
Frequency 101.7
NGR SK32448706
RDS PS Classic_
RDS PI C2A1
Switched PI C6A1
TP/TA Y
TMC Y
Lat 53.379402
Long -1.513808
Site Ht 247
In-Use Aerial Ht 37
In-UseERP/HP 250 W
In-Use ERP/VP 250 W
Max Dir 70
Licensed ERP/HP 250 W
Licensed ERP/VP 250 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
354443100244333100233332101233333101

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
354443100244333100233332101233333101