Mounteagle - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Mounteagle

Moray Firth · Classic FM · 101.4 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 2.2 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 1 dB attenuation; relative ERP 79.4% of peak 50°: 1 dB attenuation; relative ERP 79.4% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 1 dB attenuation; relative ERP 79.4% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 8 dB attenuation; relative ERP 15.8% of peak 240°: 10 dB attenuation; relative ERP 10% of peak 250°: 12 dB attenuation; relative ERP 6.3% of peak 260°: 12 dB attenuation; relative ERP 6.3% of peak 270°: 12 dB attenuation; relative ERP 6.3% of peak 280°: 12 dB attenuation; relative ERP 6.3% of peak 290°: 12 dB attenuation; relative ERP 6.3% of peak 300°: 12 dB attenuation; relative ERP 6.3% of peak 310°: 10 dB attenuation; relative ERP 10% of peak 320°: 8 dB attenuation; relative ERP 15.8% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 3 dB attenuation; relative ERP 50.1% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 170°, 180° at 0 dB attenuation.

Deepest restriction(s): 250°, 260°, 270°, 280°, 290°, 300° at 12 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 8.8 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 1 dB attenuation; relative ERP 79.4% of peak 50°: 1 dB attenuation; relative ERP 79.4% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 1 dB attenuation; relative ERP 79.4% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 8 dB attenuation; relative ERP 15.8% of peak 240°: 10 dB attenuation; relative ERP 10% of peak 250°: 12 dB attenuation; relative ERP 6.3% of peak 260°: 12 dB attenuation; relative ERP 6.3% of peak 270°: 12 dB attenuation; relative ERP 6.3% of peak 280°: 12 dB attenuation; relative ERP 6.3% of peak 290°: 12 dB attenuation; relative ERP 6.3% of peak 300°: 12 dB attenuation; relative ERP 6.3% of peak 310°: 10 dB attenuation; relative ERP 10% of peak 320°: 8 dB attenuation; relative ERP 15.8% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 3 dB attenuation; relative ERP 50.1% of peak 350°: 2 dB attenuation; relative ERP 63.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 70°, 80°, 90°, 100°, 110°, 120°, 130°, 170°, 180° at 0 dB attenuation.

Deepest restriction(s): 250°, 260°, 270°, 280°, 290°, 300° at 12 dB attenuation.

Parameters

Date 20/11/1996
Station Classic FM
Area Moray Firth
Site Mounteagle
Licence AN000001
mb21 Mounteagle
Frequency 101.4
NGR NH64005802
RDS PS Classic_
RDS PI C2A1
Switched PI C5A1
TP/TA Y
TMC Y
Lat 57.591655
Long -4.276832
Site Ht 212
In-Use Aerial Ht 206
In-UseERP/HP 2.2 kW
In-Use ERP/VP 8.8 kW
Max Dir 100
Licensed ERP/HP 25 kW
Licensed ERP/VP 25 kW

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
00001110000000111001236810121212121212108632

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
00001110000000111001236810121212121212108632