Morecambe Bay - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Morecambe Bay

Morecambe Bay · Classic FM · 101.8 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 3.2 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 20 dB attenuation; relative ERP 1% of peak 10°: 20 dB attenuation; relative ERP 1% of peak 20°: 20 dB attenuation; relative ERP 1% of peak 30°: 20 dB attenuation; relative ERP 1% of peak 40°: 20 dB attenuation; relative ERP 1% of peak 50°: 14 dB attenuation; relative ERP 4% of peak 60°: 8 dB attenuation; relative ERP 15.8% of peak 70°: 6 dB attenuation; relative ERP 25.1% of peak 80°: 4 dB attenuation; relative ERP 39.8% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 1 dB attenuation; relative ERP 79.4% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 4 dB attenuation; relative ERP 39.8% of peak 170°: 6 dB attenuation; relative ERP 25.1% of peak 180°: 8 dB attenuation; relative ERP 15.8% of peak 190°: 14 dB attenuation; relative ERP 4% of peak 200°: 20 dB attenuation; relative ERP 1% of peak 210°: 20 dB attenuation; relative ERP 1% of peak 220°: 20 dB attenuation; relative ERP 1% of peak 230°: 20 dB attenuation; relative ERP 1% of peak 240°: 20 dB attenuation; relative ERP 1% of peak 250°: 15 dB attenuation; relative ERP 3.2% of peak 260°: 14 dB attenuation; relative ERP 4% of peak 270°: 12 dB attenuation; relative ERP 6.3% of peak 280°: 10 dB attenuation; relative ERP 10% of peak 290°: 9 dB attenuation; relative ERP 12.6% of peak 300°: 9 dB attenuation; relative ERP 12.6% of peak 310°: 9 dB attenuation; relative ERP 12.6% of peak 320°: 10 dB attenuation; relative ERP 10% of peak 330°: 12 dB attenuation; relative ERP 6.3% of peak 340°: 14 dB attenuation; relative ERP 4% of peak 350°: 15 dB attenuation; relative ERP 3.2% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 110°, 120°, 130° at 0 dB attenuation.

Deepest restriction(s): 0°, 10°, 20°, 30°, 40°, 200°, 210°, 220°, 230°, 240° at 20 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 3.2 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 10 dB attenuation; relative ERP 10% of peak 10°: 8 dB attenuation; relative ERP 15.8% of peak 20°: 6 dB attenuation; relative ERP 25.1% of peak 30°: 4 dB attenuation; relative ERP 39.8% of peak 40°: 3 dB attenuation; relative ERP 50.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 1 dB attenuation; relative ERP 79.4% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 2 dB attenuation; relative ERP 63.1% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 4 dB attenuation; relative ERP 39.8% of peak 220°: 6 dB attenuation; relative ERP 25.1% of peak 230°: 8 dB attenuation; relative ERP 15.8% of peak 240°: 10 dB attenuation; relative ERP 10% of peak 250°: 10 dB attenuation; relative ERP 10% of peak 260°: 10 dB attenuation; relative ERP 10% of peak 270°: 10 dB attenuation; relative ERP 10% of peak 280°: 9 dB attenuation; relative ERP 12.6% of peak 290°: 9 dB attenuation; relative ERP 12.6% of peak 300°: 9 dB attenuation; relative ERP 12.6% of peak 310°: 9 dB attenuation; relative ERP 12.6% of peak 320°: 10 dB attenuation; relative ERP 10% of peak 330°: 10 dB attenuation; relative ERP 10% of peak 340°: 10 dB attenuation; relative ERP 10% of peak 350°: 10 dB attenuation; relative ERP 10% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 90°, 100°, 110°, 120°, 130°, 140°, 150° at 0 dB attenuation.

Deepest restriction(s): 0°, 240°, 250°, 260°, 270°, 320°, 330°, 340°, 350° at 10 dB attenuation.

Licensed horizontal pattern

ERP field: Licensed ERP/HP = 5 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 10 dB attenuation; relative ERP 10% of peak 10°: 7 dB attenuation; relative ERP 20% of peak 20°: 5 dB attenuation; relative ERP 31.6% of peak 30°: 3 dB attenuation; relative ERP 50.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 5 dB attenuation; relative ERP 31.6% of peak 230°: 7 dB attenuation; relative ERP 20% of peak 240°: 10 dB attenuation; relative ERP 10% of peak 250°: 12 dB attenuation; relative ERP 6.3% of peak 260°: 14 dB attenuation; relative ERP 4% of peak 270°: 14 dB attenuation; relative ERP 4% of peak 280°: 14 dB attenuation; relative ERP 4% of peak 290°: 14 dB attenuation; relative ERP 4% of peak 300°: 14 dB attenuation; relative ERP 4% of peak 310°: 14 dB attenuation; relative ERP 4% of peak 320°: 14 dB attenuation; relative ERP 4% of peak 330°: 14 dB attenuation; relative ERP 4% of peak 340°: 14 dB attenuation; relative ERP 4% of peak 350°: 12 dB attenuation; relative ERP 6.3% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170° at 0 dB attenuation.

Deepest restriction(s): 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 14 dB attenuation.

Licensed vertical pattern

ERP field: Licensed ERP/VP = 5 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 10 dB attenuation; relative ERP 10% of peak 10°: 7 dB attenuation; relative ERP 20% of peak 20°: 5 dB attenuation; relative ERP 31.6% of peak 30°: 3 dB attenuation; relative ERP 50.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 1 dB attenuation; relative ERP 79.4% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0 dB attenuation; relative ERP 100% of peak 100°: 0 dB attenuation; relative ERP 100% of peak 110°: 0 dB attenuation; relative ERP 100% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 1 dB attenuation; relative ERP 79.4% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 3 dB attenuation; relative ERP 50.1% of peak 220°: 5 dB attenuation; relative ERP 31.6% of peak 230°: 7 dB attenuation; relative ERP 20% of peak 240°: 10 dB attenuation; relative ERP 10% of peak 250°: 12 dB attenuation; relative ERP 6.3% of peak 260°: 14 dB attenuation; relative ERP 4% of peak 270°: 14 dB attenuation; relative ERP 4% of peak 280°: 14 dB attenuation; relative ERP 4% of peak 290°: 14 dB attenuation; relative ERP 4% of peak 300°: 14 dB attenuation; relative ERP 4% of peak 310°: 14 dB attenuation; relative ERP 4% of peak 320°: 14 dB attenuation; relative ERP 4% of peak 330°: 14 dB attenuation; relative ERP 4% of peak 340°: 14 dB attenuation; relative ERP 4% of peak 350°: 12 dB attenuation; relative ERP 6.3% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 80°, 90°, 100°, 110°, 120°, 130°, 140°, 150°, 160°, 170° at 0 dB attenuation.

Deepest restriction(s): 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 14 dB attenuation.

Parameters

Date 18/12/1996
Station Classic FM
Area Morecambe Bay
Site Morecambe Bay
Licence AN000001
mb21 Morecambe Bay
Frequency 101.8
NGR SD23967916
RDS PS Classic_
RDS PI C2A1
Switched PI C6A1
TP/TA Y
TMC Y
Lat 54.202526
Long -3.167193
Site Ht 259
In-Use Aerial Ht 67
In-UseERP/HP 3.2 kW
In-Use ERP/VP 3.2 kW
Max Dir 120
Licensed ERP/HP 5 kW
Licensed ERP/VP 5 kW

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
20202020201486421000124681420202020201514121099910121415

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
108643211100000001112346810101010999910101010

Licensed horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
1075322110000000000112357101214141414141414141412

Licensed vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
1075322110000000000112357101214141414141414141412