Angus - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Angus

Tayside · Classic FM · 100.1 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 2.1 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 5 dB attenuation; relative ERP 31.6% of peak 10°: 3 dB attenuation; relative ERP 50.1% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 1 dB attenuation; relative ERP 79.4% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 4 dB attenuation; relative ERP 39.8% of peak 120°: 4 dB attenuation; relative ERP 39.8% of peak 130°: 4 dB attenuation; relative ERP 39.8% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 1 dB attenuation; relative ERP 79.4% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 1 dB attenuation; relative ERP 79.4% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 3 dB attenuation; relative ERP 50.1% of peak 240°: 4 dB attenuation; relative ERP 39.8% of peak 250°: 5 dB attenuation; relative ERP 31.6% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 8 dB attenuation; relative ERP 15.8% of peak 280°: 10 dB attenuation; relative ERP 10% of peak 290°: 11 dB attenuation; relative ERP 7.9% of peak 300°: 12 dB attenuation; relative ERP 6.3% of peak 310°: 12 dB attenuation; relative ERP 6.3% of peak 320°: 12 dB attenuation; relative ERP 6.3% of peak 330°: 11 dB attenuation; relative ERP 7.9% of peak 340°: 9 dB attenuation; relative ERP 12.6% of peak 350°: 6 dB attenuation; relative ERP 25.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 40°, 50°, 60°, 70°, 180°, 190°, 200° at 0 dB attenuation.

Deepest restriction(s): 300°, 310°, 320° at 12 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 8.2 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 5 dB attenuation; relative ERP 31.6% of peak 10°: 3 dB attenuation; relative ERP 50.1% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 1 dB attenuation; relative ERP 79.4% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 3 dB attenuation; relative ERP 50.1% of peak 110°: 4 dB attenuation; relative ERP 39.8% of peak 120°: 4 dB attenuation; relative ERP 39.8% of peak 130°: 4 dB attenuation; relative ERP 39.8% of peak 140°: 3 dB attenuation; relative ERP 50.1% of peak 150°: 2 dB attenuation; relative ERP 63.1% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 1 dB attenuation; relative ERP 79.4% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 1 dB attenuation; relative ERP 79.4% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 3 dB attenuation; relative ERP 50.1% of peak 240°: 4 dB attenuation; relative ERP 39.8% of peak 250°: 5 dB attenuation; relative ERP 31.6% of peak 260°: 6 dB attenuation; relative ERP 25.1% of peak 270°: 8 dB attenuation; relative ERP 15.8% of peak 280°: 10 dB attenuation; relative ERP 10% of peak 290°: 11 dB attenuation; relative ERP 7.9% of peak 300°: 12 dB attenuation; relative ERP 6.3% of peak 310°: 12 dB attenuation; relative ERP 6.3% of peak 320°: 12 dB attenuation; relative ERP 6.3% of peak 330°: 11 dB attenuation; relative ERP 7.9% of peak 340°: 9 dB attenuation; relative ERP 12.6% of peak 350°: 6 dB attenuation; relative ERP 25.1% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 40°, 50°, 60°, 70°, 180°, 190°, 200° at 0 dB attenuation.

Deepest restriction(s): 300°, 310°, 320° at 12 dB attenuation.

Parameters

Date 15/10/1993
Station Classic FM
Area Tayside
Site Angus
Licence AN000001
mb21 Angus
Frequency 100.1
NGR NO39484078
RDS PS Classic_
RDS PI C2A1
Switched PI C5A1
TP/TA Y
TMC Y
Lat 56.555079
Long -2.986126
Site Ht 312
In-Use Aerial Ht 165
In-UseERP/HP 2.1 kW
In-Use ERP/VP 8.2 kW
Max Dir 120
Licensed ERP/HP 8.5 kW
Licensed ERP/VP 8.5 kW

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
532100001234443211000123456810111212121196

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
532100001234443211000123456810111212121196