In-use vertical pattern
ERP field: In-Use ERP/VP = 25 W
0°
30°
60°
90°
120°
150°
180°
210°
240°
270°
300°
330°
N
E
S
W
0°: 0 dB attenuation; relative ERP 100% of peak
10°: 0 dB attenuation; relative ERP 100% of peak
20°: 0 dB attenuation; relative ERP 100% of peak
30°: 0 dB attenuation; relative ERP 100% of peak
40°: 0 dB attenuation; relative ERP 100% of peak
50°: 0 dB attenuation; relative ERP 100% of peak
60°: 0 dB attenuation; relative ERP 100% of peak
70°: 0 dB attenuation; relative ERP 100% of peak
80°: 0 dB attenuation; relative ERP 100% of peak
90°: 0 dB attenuation; relative ERP 100% of peak
100°: 0.5 dB attenuation; relative ERP 89.1% of peak
110°: 0.75 dB attenuation; relative ERP 84.1% of peak
120°: 1.5 dB attenuation; relative ERP 70.8% of peak
130°: 2.25 dB attenuation; relative ERP 59.6% of peak
140°: 3 dB attenuation; relative ERP 50.1% of peak
150°: 3.5 dB attenuation; relative ERP 44.7% of peak
160°: 4 dB attenuation; relative ERP 39.8% of peak
170°: 4 dB attenuation; relative ERP 39.8% of peak
180°: 4 dB attenuation; relative ERP 39.8% of peak
190°: 4 dB attenuation; relative ERP 39.8% of peak
200°: 4 dB attenuation; relative ERP 39.8% of peak
210°: 4 dB attenuation; relative ERP 39.8% of peak
220°: 4 dB attenuation; relative ERP 39.8% of peak
230°: 4 dB attenuation; relative ERP 39.8% of peak
240°: 4 dB attenuation; relative ERP 39.8% of peak
250°: 3.6 dB attenuation; relative ERP 43.7% of peak
260°: 3.2 dB attenuation; relative ERP 47.9% of peak
270°: 2.5 dB attenuation; relative ERP 56.2% of peak
280°: 2 dB attenuation; relative ERP 63.1% of peak
290°: 1.5 dB attenuation; relative ERP 70.8% of peak
300°: 1.25 dB attenuation; relative ERP 75% of peak
310°: 1 dB attenuation; relative ERP 79.4% of peak
320°: 0.75 dB attenuation; relative ERP 84.1% of peak
330°: 0.5 dB attenuation; relative ERP 89.1% of peak
340°: 0.25 dB attenuation; relative ERP 94.4% of peak
350°: 0 dB attenuation; relative ERP 100% of peak
Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20 .
Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 90°, 350° at 0 dB attenuation.
Deepest restriction(s): 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240° at 4 dB attenuation.