Glasgow - Grafton Place - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Glasgow - Grafton Place

Glasgow · Celtic Music Radio · 95 MHz

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 50 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 0 dB attenuation; relative ERP 100% of peak 10°: 0 dB attenuation; relative ERP 100% of peak 20°: 0 dB attenuation; relative ERP 100% of peak 30°: 0 dB attenuation; relative ERP 100% of peak 40°: 0 dB attenuation; relative ERP 100% of peak 50°: 0 dB attenuation; relative ERP 100% of peak 60°: 0 dB attenuation; relative ERP 100% of peak 70°: 0 dB attenuation; relative ERP 100% of peak 80°: 0 dB attenuation; relative ERP 100% of peak 90°: 0.5 dB attenuation; relative ERP 89.1% of peak 100°: 1 dB attenuation; relative ERP 79.4% of peak 110°: 1.3 dB attenuation; relative ERP 74.1% of peak 120°: 1.5 dB attenuation; relative ERP 70.8% of peak 130°: 1.7 dB attenuation; relative ERP 67.6% of peak 140°: 2 dB attenuation; relative ERP 63.1% of peak 150°: 2.2 dB attenuation; relative ERP 60.3% of peak 160°: 2.5 dB attenuation; relative ERP 56.2% of peak 170°: 3 dB attenuation; relative ERP 50.1% of peak 180°: 3 dB attenuation; relative ERP 50.1% of peak 190°: 3 dB attenuation; relative ERP 50.1% of peak 200°: 2.5 dB attenuation; relative ERP 56.2% of peak 210°: 2.2 dB attenuation; relative ERP 60.3% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 1.8 dB attenuation; relative ERP 66.1% of peak 240°: 1.6 dB attenuation; relative ERP 69.2% of peak 250°: 1.5 dB attenuation; relative ERP 70.8% of peak 260°: 1.3 dB attenuation; relative ERP 74.1% of peak 270°: 1 dB attenuation; relative ERP 79.4% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0 dB attenuation; relative ERP 100% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 0°, 10°, 20°, 30°, 40°, 50°, 60°, 70°, 80°, 280°, 290°, 300°, 310°, 320°, 330°, 340°, 350° at 0 dB attenuation.

Deepest restriction(s): 170°, 180°, 190° at 3 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 50 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 5 dB attenuation; relative ERP 31.6% of peak 10°: 4.7 dB attenuation; relative ERP 33.9% of peak 20°: 4.5 dB attenuation; relative ERP 35.5% of peak 30°: 4.2 dB attenuation; relative ERP 38% of peak 40°: 4 dB attenuation; relative ERP 39.8% of peak 50°: 3.7 dB attenuation; relative ERP 42.7% of peak 60°: 3.4 dB attenuation; relative ERP 45.7% of peak 70°: 3 dB attenuation; relative ERP 50.1% of peak 80°: 2 dB attenuation; relative ERP 63.1% of peak 90°: 1.7 dB attenuation; relative ERP 67.6% of peak 100°: 1.5 dB attenuation; relative ERP 70.8% of peak 110°: 1 dB attenuation; relative ERP 79.4% of peak 120°: 0.5 dB attenuation; relative ERP 89.1% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 0 dB attenuation; relative ERP 100% of peak 170°: 0 dB attenuation; relative ERP 100% of peak 180°: 0 dB attenuation; relative ERP 100% of peak 190°: 0 dB attenuation; relative ERP 100% of peak 200°: 0 dB attenuation; relative ERP 100% of peak 210°: 0 dB attenuation; relative ERP 100% of peak 220°: 0 dB attenuation; relative ERP 100% of peak 230°: 0 dB attenuation; relative ERP 100% of peak 240°: 0 dB attenuation; relative ERP 100% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1.5 dB attenuation; relative ERP 70.8% of peak 270°: 2 dB attenuation; relative ERP 63.1% of peak 280°: 2.7 dB attenuation; relative ERP 53.7% of peak 290°: 3.5 dB attenuation; relative ERP 44.7% of peak 300°: 4 dB attenuation; relative ERP 39.8% of peak 310°: 4.5 dB attenuation; relative ERP 35.5% of peak 320°: 5 dB attenuation; relative ERP 31.6% of peak 330°: 5 dB attenuation; relative ERP 31.6% of peak 340°: 5 dB attenuation; relative ERP 31.6% of peak 350°: 5 dB attenuation; relative ERP 31.6% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 130°, 140°, 150°, 160°, 170°, 180°, 190°, 200°, 210°, 220°, 230°, 240° at 0 dB attenuation.

Deepest restriction(s): 0°, 320°, 330°, 340°, 350° at 5 dB attenuation.

Parameters

Date 13/09/2021
Station Celtic Music Radio
Area Glasgow
Site Glasgow - Grafton Place
Licence CR000257
mb21 Glasgow (Grafton Place)
Frequency 95
NGR NS59556573
RDS PS Celt95fm
RDS PI CD89
Switched PI
TP/TA N
TMC N
Lat 55.864222
Long -4.24582
Site Ht 40
In-Use Aerial Ht 84
In-UseERP/HP 50 W
In-Use ERP/VP 50 W
Max Dir
Licensed ERP/HP 50.1 W
Licensed ERP/VP 50.1 W

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
0000000000.511.31.51.722.22.53332.52.221.81.61.51.3100000000

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
54.74.54.243.73.4321.71.510.500000000000011.522.73.544.55555