High Hunsley - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

High Hunsley

North Humberside · Capital · 105.8 MHz

Historic names: 105 Capital FM, Galaxy Yorkshire, Galaxy 105, Kiss 105 (licence AL000190)

Antenna pattern

In-use horizontal pattern

ERP field: In-UseERP/HP = 4.6 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 3 dB attenuation; relative ERP 50.1% of peak 10°: 2 dB attenuation; relative ERP 63.1% of peak 20°: 1 dB attenuation; relative ERP 79.4% of peak 30°: 2 dB attenuation; relative ERP 63.1% of peak 40°: 2 dB attenuation; relative ERP 63.1% of peak 50°: 2 dB attenuation; relative ERP 63.1% of peak 60°: 2 dB attenuation; relative ERP 63.1% of peak 70°: 2 dB attenuation; relative ERP 63.1% of peak 80°: 2 dB attenuation; relative ERP 63.1% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 2 dB attenuation; relative ERP 63.1% of peak 110°: 1 dB attenuation; relative ERP 79.4% of peak 120°: 0 dB attenuation; relative ERP 100% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 1 dB attenuation; relative ERP 79.4% of peak 170°: 2 dB attenuation; relative ERP 63.1% of peak 180°: 2 dB attenuation; relative ERP 63.1% of peak 190°: 2 dB attenuation; relative ERP 63.1% of peak 200°: 2 dB attenuation; relative ERP 63.1% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 1 dB attenuation; relative ERP 79.4% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 2 dB attenuation; relative ERP 63.1% of peak 280°: 4 dB attenuation; relative ERP 39.8% of peak 290°: 6 dB attenuation; relative ERP 25.1% of peak 300°: 7 dB attenuation; relative ERP 20% of peak 310°: 7 dB attenuation; relative ERP 20% of peak 320°: 7 dB attenuation; relative ERP 20% of peak 330°: 7 dB attenuation; relative ERP 20% of peak 340°: 5 dB attenuation; relative ERP 31.6% of peak 350°: 4 dB attenuation; relative ERP 39.8% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 120°, 130°, 140°, 150° at 0 dB attenuation.

Deepest restriction(s): 300°, 310°, 320°, 330° at 7 dB attenuation.

In-use vertical pattern

ERP field: In-Use ERP/VP = 5 kW

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 4 dB attenuation; relative ERP 39.8% of peak 10°: 2 dB attenuation; relative ERP 63.1% of peak 20°: 1 dB attenuation; relative ERP 79.4% of peak 30°: 2 dB attenuation; relative ERP 63.1% of peak 40°: 3 dB attenuation; relative ERP 50.1% of peak 50°: 3 dB attenuation; relative ERP 50.1% of peak 60°: 2 dB attenuation; relative ERP 63.1% of peak 70°: 1 dB attenuation; relative ERP 79.4% of peak 80°: 1 dB attenuation; relative ERP 79.4% of peak 90°: 2 dB attenuation; relative ERP 63.1% of peak 100°: 4 dB attenuation; relative ERP 39.8% of peak 110°: 4 dB attenuation; relative ERP 39.8% of peak 120°: 2 dB attenuation; relative ERP 63.1% of peak 130°: 0 dB attenuation; relative ERP 100% of peak 140°: 0 dB attenuation; relative ERP 100% of peak 150°: 0 dB attenuation; relative ERP 100% of peak 160°: 3 dB attenuation; relative ERP 50.1% of peak 170°: 4 dB attenuation; relative ERP 39.8% of peak 180°: 3 dB attenuation; relative ERP 50.1% of peak 190°: 1 dB attenuation; relative ERP 79.4% of peak 200°: 1 dB attenuation; relative ERP 79.4% of peak 210°: 2 dB attenuation; relative ERP 63.1% of peak 220°: 4 dB attenuation; relative ERP 39.8% of peak 230°: 4 dB attenuation; relative ERP 39.8% of peak 240°: 3 dB attenuation; relative ERP 50.1% of peak 250°: 1 dB attenuation; relative ERP 79.4% of peak 260°: 1 dB attenuation; relative ERP 79.4% of peak 270°: 3 dB attenuation; relative ERP 50.1% of peak 280°: 6 dB attenuation; relative ERP 25.1% of peak 290°: 8 dB attenuation; relative ERP 15.8% of peak 300°: 6 dB attenuation; relative ERP 25.1% of peak 310°: 4 dB attenuation; relative ERP 39.8% of peak 320°: 4 dB attenuation; relative ERP 39.8% of peak 330°: 6 dB attenuation; relative ERP 25.1% of peak 340°: 8 dB attenuation; relative ERP 15.8% of peak 350°: 8 dB attenuation; relative ERP 15.8% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 130°, 140°, 150° at 0 dB attenuation.

Deepest restriction(s): 290°, 340°, 350° at 8 dB attenuation.

Parameters

Date 09/01/1997
Station Capital
Area North Humberside
Site High Hunsley
Licence AL000190
mb21 High Hunsley
MCA map Open Ofcom MCA map
Frequency 105.8
NGR SE94583504
RDS PS CAPITAL_
RDS PI C370
Switched PI C570
TP/TA Y
TMC
Lat 53.80307
Long -0.56537
Site Ht 164
In-Use Aerial Ht 64
In-UseERP/HP 4.6 kW
In-Use ERP/VP 5 kW
Max Dir 135
Licensed ERP/HP 5 kW
Licensed ERP/VP 5 kW

Pattern values

In-use horizontal pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
321222222221000012222221111246777754

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
421233211244200034311244311368644688