Blackburn - Hospital - Ofcom TX Visualiser

← Back to FM/VHF search · Map this site name · Offline SVG map

Blackburn - Hospital

Blackburn · Capital · 107 MHz

Historic names: 2BR, 107 The Bee, The Bee (licence AL101643)

Antenna pattern

In-use vertical pattern

ERP field: In-Use ERP/VP = 250 W

30° 60° 90° 120° 150° 180° 210° 240° 270° 300° 330° N E S W 0°: 1 dB attenuation; relative ERP 79.4% of peak 10°: 1.5 dB attenuation; relative ERP 70.8% of peak 20°: 2 dB attenuation; relative ERP 63.1% of peak 30°: 2.5 dB attenuation; relative ERP 56.2% of peak 40°: 3 dB attenuation; relative ERP 50.1% of peak 50°: 3.5 dB attenuation; relative ERP 44.7% of peak 60°: 4 dB attenuation; relative ERP 39.8% of peak 70°: 4.5 dB attenuation; relative ERP 35.5% of peak 80°: 4.8 dB attenuation; relative ERP 33.1% of peak 90°: 5 dB attenuation; relative ERP 31.6% of peak 100°: 5 dB attenuation; relative ERP 31.6% of peak 110°: 5 dB attenuation; relative ERP 31.6% of peak 120°: 5 dB attenuation; relative ERP 31.6% of peak 130°: 5 dB attenuation; relative ERP 31.6% of peak 140°: 5 dB attenuation; relative ERP 31.6% of peak 150°: 5 dB attenuation; relative ERP 31.6% of peak 160°: 4.8 dB attenuation; relative ERP 33.1% of peak 170°: 4.5 dB attenuation; relative ERP 35.5% of peak 180°: 4 dB attenuation; relative ERP 39.8% of peak 190°: 3.5 dB attenuation; relative ERP 44.7% of peak 200°: 3 dB attenuation; relative ERP 50.1% of peak 210°: 2.5 dB attenuation; relative ERP 56.2% of peak 220°: 2 dB attenuation; relative ERP 63.1% of peak 230°: 1.5 dB attenuation; relative ERP 70.8% of peak 240°: 1 dB attenuation; relative ERP 79.4% of peak 250°: 0.4 dB attenuation; relative ERP 91.2% of peak 260°: 0 dB attenuation; relative ERP 100% of peak 270°: 0 dB attenuation; relative ERP 100% of peak 280°: 0 dB attenuation; relative ERP 100% of peak 290°: 0 dB attenuation; relative ERP 100% of peak 300°: 0 dB attenuation; relative ERP 100% of peak 310°: 0 dB attenuation; relative ERP 100% of peak 320°: 0 dB attenuation; relative ERP 100% of peak 330°: 0 dB attenuation; relative ERP 100% of peak 340°: 0 dB attenuation; relative ERP 100% of peak 350°: 0.4 dB attenuation; relative ERP 91.2% of peak

Pattern values are treated as dB attenuation. The outer ring is the lowest attenuation / strongest direction; radius uses field-strength scaling: 10−dB/20.

Best bearing(s): 260°, 270°, 280°, 290°, 300°, 310°, 320°, 330°, 340° at 0 dB attenuation.

Deepest restriction(s): 90°, 100°, 110°, 120°, 130°, 140°, 150° at 5 dB attenuation.

Parameters

Date 27/09/2005
Station Capital
Area Blackburn
Site Blackburn - Hospital
Licence AL101643
mb21 Blackburn (Hospital)
MCA map Open Ofcom MCA map
Frequency 107
NGR SD69602673
RDS PS CAPITAL_
RDS PI C37C
Switched PI C57C
TP/TA Y
TMC
Lat 53.736064
Long -2.462328
Site Ht 201
In-Use Aerial Ht 32
In-UseERP/HP 250 W
In-Use ERP/VP 250 W
Max Dir 300
Licensed ERP/HP 250 W
Licensed ERP/VP 250 W

Pattern values

In-use vertical pattern

10°20°30°40°50°60°70°80°90°100°110°120°130°140°150°160°170°180°190°200°210°220°230°240°250°260°270°280°290°300°310°320°330°340°350°
11.522.533.544.54.855555554.84.543.532.521.510.40000000000.4